Parameter
Start address (hex) Byte count
Data type
Unit
Reset
00 0B
1
Status flag
-
01
Reset
⚫
Function code available: 10
⚫
The control authority (start address 00 09) should be set to 01 (remote control)
to permit writing.
Parameter
Start address (hex) Byte count
Data type
Unit
Input voltage
04 C0
4
Single-precision
floating-point
value
V
Output voltage
04 C4
4
V
Output current
04 C8
4
A
⚫
Function code available: 03
Parameter
Start address (hex) Byte count
Data type
Unit
Device status
04 CC
1
Status flag
-
Bit-7
1: OTP
Bit-6
1: OCP
Bit-5
1: OVP
Bit-4
1: Vin UV
Bit-3
1: Vin OV
Bit-2
1: Output at CC mode
Bit-1
1: Output at CV mode
Bit-0
Reserved
⚫
Function code available: 03
Parameter
Start address (hex) Byte count
Data type
Unit
OVP point
01 D3
4
Single-precision
floating-point
value
V
OCP point
01 D7
4
A
⚫
Function code available: 03, 10
⚫
The control authority (start address 00 09) should be set to 01 (remote control)
to permit writing.