For technical questions, please call 1-888-866-5797.
Item 69677
SAFETY
OPERA
TION
MAINTENANCE
SETUP
Connecting Electrical Loads
Familiarize yourself with the engine controls, power panel and how to start the engine before using the generator.
Calculate the wattage of the products you will use with the generator and verify that the generator can handle the
total load.
WARNING!
Connect only properly wired plugs to the generator.
A plug that is spliced onto a different cord may be hazardous.
Only a qualified electrician should wire a plug onto a cord.
CAUTION
Never exceed the rated capacity for this
Generator, as serious damage to the Generator and/
or appliances, tools, and equipment could result from
an overload. Starting and running wattage requirements
should always be calculated when matching this
Generator’s wattage capacity to the appliance, tool, or equipment.
Use the DC12V Receptacle to power 12VDC equipment.
WARNING!
Do not charge batteries without a proper charge controller. Do not overcharge.
a. Connect the items that require the most wattage first.
b. Connect “inductive” load appliances, tools, and equipment next. Inductive
loads are small hand tools and some small appliances.
c. Connect any lights next.
d. Voltage sensitive appliances, tools, and equipment should be the last to be connected to the Generator.
Plug voltage sensitive items such as TVs, DVD players, microwaves, and cordless telephones into a UL®
Listed voltage surge protector (not included). Then, connect the surge protector into the Generator.
IMPORTANT!
Failure to connect and operate appliances, tools, and equipment in this sequence can cause
damage to the Generator, appliances, tools, and equipment and will
void
the Warranty of this Generator.
Note:
If Engine speed or voltage fluctuates with a load below the Generator’s running wattage, move the Engine
Choke Lever to the
position.
Evenly distributed
over outlets:
IF
ANY CIRCUIT BREAKERS TRIP CHECK THE FOLLOWING:
1. Make sure that
ALL circuit breakers
are reset
before starting the generator again.
2. Adjust the plugs so the loads are
shared across outlet circuits.
To achieve rated output from the generator,
distribute loads over outlets.
1,000
400
200
1,200
Tota
l Ru
nnin
g W
atts
(mu
st b
e les
s th
an 3
,200
)
4,20
0
Larg
est A
ddit
iona
l Sta
rt-up
Wa
tts
1,200
l Sta
rtup
Wa
tts n
eed
ed f
or a
ll lo
ads
(mu
st b
e les
s th
an 4
,000
)
5,40
0
Must b e
Less than
8,750
Must b e
Less than
7,000