SETUP

Before using the Generator, check that the products 

you want to plug into the unit are below the rated and 

maximum wattage ratings of the Generator. Use the 

Wattage Calculation Table below, and the watts listed 

on your products, to help calculate multiple  

wattage totals.   

 

To use the table:

1.  Add up the Running Watts for all items you 

would like to use at any given time

2.  Make sure that this total is under the 7,000 

running wattage of the generator.

3.  Find the single highest starting watts for 

the selected items and add to the total. 

4.  Make sure that this total is under the 

8,750 peak wattage of the generator.

5.  Plug in and turn on products from largest wattage 

to smallest. 

 

 

Example

Equipment

Running

Watts

Total Running Watts  

(must be less than 7,000)

Largest Additional Start-up Watts

Total Startup Watts needed for all loads 

(must be less than 8,750)

Wattage Calculation Table

Equipment

Running

Watts

Total Running Watts  

(must be less than 7,000)

Largest Additional Start-up Watts

Total Startup Watts needed for all loads 

(must be less than 8,750)

A generator that is rated more than the minimum 

required peak watts will last much longer than a 

generator that only supplies the exact watts needed.

To Calculate Wattage

Volts and amps can be multiplied together to get watts 

(volts x amps = watts). 

To Calculate Additional Start-Up Watts  

(If They Are Not Listed) 

 For equipment with a motor: Use the rated watts 

amount as an estimate of additional Start‑up Watts.

For most lights or heaters: 

there are no additional start‑up watts. 

Calculating Total Wattage of Devices Used with the Generator

JOB SITE

Device

Running 

Watts

Additional 

Start-up 

Watts

Air Compressor ‑ 1/2 HP

1000

1000

Table Saw ‑ 10"

1700

1300

Belt Sander ‑ 3"

1200

1200

Hand Drill ‑ 1/2"

600

600

Halogen Work Light

1000

0

Recipricating Saw

900

900

HOUSEHOLD

Device

Running 

Watts

Additional 

Start-up 

Watts

Computer w/ Monitor

800

0

Electric Clothes Dryer

5500

500

Electric Range

2100

0

Electric Water Heater

2000

0

Light Bulb ‑ 100 watts

100

0

Microwave ‑ 1000 watts

1000

200

Sump Pump ‑ 1/2 HP

1000

1100

Television

400

0

Washing Machine

1100

1100

Well Pump ‑ 1/2 HP

1000

1000

RECREATION

Device

Running 

Watts

Additional 

Start-up 

Watts

AM/FM Radio

100

0

Electric Grill

1700

0

Inflator Pump

50

100

CD/DVD Player

100

0

Box Fan ‑ 20"

200

200

Coffee Maker

600

0

LAWN & GARDEN

Device

Running 

Watts

Additional 

Start-up 

Watts

Hedge Trimmer

400

400

Pressure Washer

1200

1200

Lawn Mower

1200

1200

Edger

1000

1000

HEATING & COOLING

Device

Running 

Watts

Additional 

Start-up 

Watts

Central AC ‑ 10,000 BTU

1500

1500

Furnace Fan ‑ 1/2 HP

900

1400

Space Heater

1800

0

Window AC ‑ 10,000 BTU

1200

600

EMERGENCY

Device

Running 

Watts

Additional 

Start-up 

Watts

Refrigerator/Freezer

700

1500

Radio

100

0

Wattage Estimate Charts

Note:

 Wattages listed below are estimates 

for that type of equipment only. 

Check nameplate wattages on all loads 

before connecting to Generator. 

Содержание 69677

Страница 1: ...r future reference Owner s Manual Safety Instructions Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER use in...

Страница 2: ...ne fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store fuel or other flammable materials nearby 2 Have multiple ABC class fire extinguis...

Страница 3: ...Keep all spectators at least six feet from the Engine during operation 7 Fire Hazard Do not fill gas tank while engine is running Do not operate if gasoline has been spilled Clean spilled gasoline bef...

Страница 4: ...m exposed live electrical parts and connections to avoid sparking or arcing These events could ignite fumes or vapors 29 Stay alert watch what you are doing and use common sense when operating this pi...

Страница 5: ...rk gloves and dust mask respirator during service 7 Maintain labels and nameplates on the equipment These carry important information If unreadable or missing contact Harbor Freight Tools for a replac...

Страница 6: ...tane stabilizer treated unleaded gasoline Capacity 6 1 Gallons 23L Engine Oil Type SAE 10W 30 above 32 F 5W 30 at 32 F or below Capacity 1 16 Quart 1 1L Run Time 50 load 12 hr Operational Volume 76 dB...

Страница 7: ...volt or 240 volt that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit breaker protects the Generator...

Страница 8: ...dio video equipment some television sets computers and printers Sensitive electronic equipment should be operated on approved inverter type generators or pure sine wave generators Note Wheel Kit item...

Страница 9: ...vel should be up to the full level as shown above 5 If the oil level is at or below the low mark add the appropriate type of oil until the oil level is at the proper level SAE 10W 30 oil is recommende...

Страница 10: ...d using the Generator disconnect all electrical loads Note Do not allow generator to run out of fuel with loads attached 5 Turn off the Engine 6 Allow the Generator and its Engine to completely cool T...

Страница 11: ...ach start up so that the engine can stabilize For MANUAL START A Turn the Engine Switch to ON B Grip the Starter Handle of the Engine loosely and pull it slowly several times to allow the gasoline to...

Страница 12: ...equipment next Inductive loads are small hand tools and some small appliances c Connect any lights next d Voltage sensitive appliances tools and equipment should be the last to be connected to the Ge...

Страница 13: ...e Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated watts amount as an estimate of additional Start up Watts For most lights or heaters there are no additional...

Страница 14: ...emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the generator and attached equipment Stopping the Engine Under Normal Conditions 1 Before turning off the Engine t...

Страница 15: ...alified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general guide If performance decreases or if equipment oper...

Страница 16: ...ore starting engine To prevent FIRE do not start the engine while the smell of fuel hangs in the air Engine Oil Change CAUTION Oil is very hot during operation and can cause burns Wait for engine to c...

Страница 17: ...rench remove the spark plug 3 Inspect the spark plug If the electrode is oily clean it using a clean dry rag If the electrode has deposits on it polish it using emery paper If the white insulator is c...

Страница 18: ...a Change engine oil b Clean out area around spark plug Remove spark plug and pour one tablespoon of engine oil into cylinder through spark plug hole c Replace spark plug but leave spark plug cap disco...

Страница 19: ...l the start handle several times to air out the chamber Reinstall spark plug and set Choke to START position 9 Replace Fuel Filter IGNITION SPARK RELATED 1 Spark plug cap not connected securely 2 Spar...

Страница 20: ...cks 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fuel tank with fresh 87 octane stabilizer treated unleade...

Страница 21: ...Contactor Assy 1 88 Bolt Washer 2 89 Coil Assy Charge 1 90 Bolt Flange 2 91 Clamper Cord 1 92 Bolt Flange 1 93 Cover Dust 1 94 Bolt Flange M5 10 3 95 Grommet Crankcase 1 96 Bolt Flange 4 97 Stay Comp...

Страница 22: ...Page 22 For technical questions please call 1 888 866 5797 Item 69677 Assembly Diagram...

Страница 23: ...ytic converter fuel tanks fuel lines fuel caps valves canisters vapor hoses clamps connectors and other emissions related assemblies Where a warrantable condition exists HFT will repair or replace at...

Страница 24: ...l be grounds for disallowing a warranty claim HFT is not liable to warrant failures of warranted parts caused by the use of a non exempted add on or modified part d Emission Warranty Parts List 1 Fuel...

Отзывы: