Setu

P

5.  If the oil level is at or below the low mark add the 

appropriate type of oil until the oil level is at the 

proper level.  SAE 10W-30 oil is recommended 

for general use.  (The SAE Viscosity Grade chart 

on page 15 in the Service section shows other 

viscosities to use in different average temperatures.)

6.  Thread the dipstick back in clockwise.

CautiOn!

  Do not run the engine with too little 

oil.  The engine will be permanently damaged.

Checking and Filling Fuel

WaRninG!

 

tO PRevent SeRiOuS 

injuRY FROm FiRe:

 

Fill the fuel tank in a well-ventilated area 

away from ignition sources.  If the engine is 

hot from use, shut the engine off and wait 

for it to cool before adding fuel. 

Do not smoke. 

1.  Clean the Fuel Cap and the area around it.

2.  Unscrew and remove the Fuel Cap.

3.  If needed, fill the Fuel Tank to about 1 inch 

under the fill neck of the Fuel Tank with 87 

octane or higher unleaded gasoline.  

note:  Do not use gasoline containing more than 

10% ethanol (e10).  Do not use e85 ethanol.

note:  Do not use gasoline that has been stored in a 

metal fuel container or a dirty fuel container.  it can 

cause particles to enter the carburetor, effecting 

engine performance and/or causing damage.

4.  Then, replace the Fuel Cap.

5.  Wipe up any spilled fuel and allow excess 

to evaporate before starting engine. 

to prevent FiRe, do not start the engine 

while the smell of fuel hangs in the air.

using the Generator

Before Starting the Generator engine

Before starting the engine:

a. 

Follow the Set up instructions 

to prepare the Generator.

b. 

unplug all loads from the Generator.

c. 

inspect the Generator and engine.

d. 

Fill the engine with the proper amount 

and type of both fuel and oil.

Basic Generator use Procedure 

  

See following pages for specific instructions
1.  Check that the generator can handle the 

wattage needed to power your products. 

2.  Start the Engine, and allow the Engine and 

Generator to run and warm up for five minutes 

after starting with no electrical load.

3.  Plug in products.
4.  When finished using the Generator, 

disconnect all electrical loads. 

note:

 Do not allow generator to run 

out of fuel with loads attached. 
5.  Turn off the Engine.
6.  Allow the Generator and its Engine to 

completely cool.  Then store the unit in a 

clean, dry, safe location out of reach of 

children and other unauthorized people.

imPORtant:

  After starting the engine, allow it to run at no load for five minutes 

with no load after each start-up so that the engine can stabilize.

7.  Break-in Period:

a.  Breaking-in the engine will help to ensure proper equipment and engine operation.
b.  The operational break-in period will last about 3 hours of use.  During this period:

•  Do not apply a heavy load to the equipment.

c.  The maintenance break-in period will last about 20 hours of use.  After this period:

•  Change the engine oil.

Under normal operating conditions subsequent maintenance follows 

the schedule explained in the SERVICE section.

Generator Pre-Start Checks (cont.)

Содержание 68527

Страница 1: ...product s serial number in the back of the manual near the assembly diagram or month and year of purchase if product has no number Keep this manual and the receipt in a safe and dry place for future...

Страница 2: ...ons should always be followed including the following Set up Precautions 1 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store...

Страница 3: ...the equipment especially while it is operating 6 Keep all spectators at least six feet from the Engine during operation 7 Fire Hazard Do not fill gas tank while engine is running Do not operate if gas...

Страница 4: ...s such as tools away from exposed live electrical parts and connections to avoid sparking or arcing These events could ignite fumes or vapors 29 Stay alert watch what you are doing and use common sens...

Страница 5: ...irator during service 6 Maintain labels and nameplates on the equipment These carry important information If unreadable or missing contact Harbor Freight Tools for a replacement 7 Have the equipment s...

Страница 6: ...F 5W 30 at 32 F or below Capacity 6 Quart 6L Run Time 50 load 10 hr Operational Volume 70 dB Available accessories Wheel kit sold separately Item 68527 The emission control system for this Generator...

Страница 7: ...nt only to the AC Receptacle that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit breaker protects th...

Страница 8: ...tem 68531 sold separately can be used with this generator Grounding The Generator must be properly grounded before use Have the unit grounded by a qualified electrician if you are not qualified to do...

Страница 9: ...tarting engine To prevent FIRE do not start the engine while the smell of fuel hangs in the air Using the Generator Before Starting the Generator Engine Before starting the engine a Follow the Set Up...

Страница 10: ...ow the gasoline to flow into the Engine s carburetor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts N...

Страница 11: ...require the most wattage first b Connect inductive load appliances tools and equipment next Inductive loads are small hand tools and some small appliances c Connect any lights next d Voltage sensitive...

Страница 12: ...d To Calculate Wattage Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated...

Страница 13: ...Stopping the Engine in an Emergency To stop the engine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the generator and attached equipment Stopping the Engi...

Страница 14: ...to safely service the equipment or engine have a qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general...

Страница 15: ...revent FIRE do not start the engine while the smell of fuel hangs in the air Engine Oil Change CAUTION Oil is very hot during operation and can cause burns Wait for engine to cool before changing oil...

Страница 16: ...plug cap from end of plug Clean out debris from around spark plug 2 Using a spark plug wrench remove the spark plug 3 Inspect the spark plug If the electrode is oily clean it using a clean dry rag If...

Страница 17: ...cup next to the bowl and allow the fuel to drain from there as well c Open the fuel valve After all fuel has drained reinstall the drain bolt and sediment cup if equipped Tighten securely 3 Lubricatio...

Страница 18: ...e to RUN position Remove spark plug and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to CHOKE position 9 Replace Fuel Filter Ignition spark Related 1 S...

Страница 19: ...e to warm up prior to operating equipment Engine knocks 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fuel...

Страница 20: ...lt 3 55 Shroud 1 56 Shroud Cylinder Body 1 57 Shield Lower 1 58 Protector Oil 1 59 Bolt 4 60 Bolt 2 61 Bolt 1 62 Collar 1 63 Bolt 1 64 Carburetor Assy 1 65 Gasket Air Cleaner 1 66 Gasket Carburetor 1...

Страница 21: ...embly Power Supply 2 117 Protector Overcurrent 1 Part Description Qty 118 Protector Overcurrent 2 119 Terminal Subassembly Grounding 1 120 Socket Subassembly DC 1 121 Switch Subassembly 1 122 Case Pan...

Страница 22: ...40 45 45 46 46 10 6 7 1 9 9 9 8 8 9 11 7 6 4 61 55 58 59 63 62 59 59 59 60 60 57 56 47 48 48 49 49 50 50 51 51 42 43 5244 41 52 3637 77 80 81 82 83 84 84 78 79 26 95 123 115 118 118 119 120 121 116 1...

Страница 23: ...on your engine for the periods of time described below provided there has been no abuse neglect or improper maintenance of your engine Your emission control system may include parts such as the carbu...

Страница 24: ...arts which are not authorized by HFT b Improper installation adjustment or repair of the engine or of any warranted part unless performed by an authorized warranty center c Failure to follow recommend...

Отзывы: