Predator 68527 Скачать руководство пользователя страница 2

Item  68527  /  68528        

      Page 2

For Pump technical questions, please call 1-800-444-3353.

For engine technical questions, please call 1-800-520-0882.

Sa
Fet

Y

O

Pe

R

ati

O

n

m

aintenan

C

e

Setu

P

table of Contents

Safety ......................................................... 2
Setup .......................................................... 6
Specifications ............................................. 6
Operation .................................................... 8

Maintenance .............................................. 14
Parts List and Diagram .............................. 20
Warranty .................................................... 23

WaRninG SYmBOlS anD DeFinitiOnS

This is the safety alert symbol.  It is used to alert you to potential personal injury hazards.  

Obey all safety messages that follow this symbol to avoid possible injury or death.

Indicates a hazardous situation which, if not avoided,  

will result in death or serious injury.

Indicates a hazardous situation which, if not avoided,  

could result in death or serious injury.

Indicates a hazardous situation which, if not avoided,  

could result in minor or moderate injury.

Addresses practices not related to personal injury.

imPORtant SaFetY inStRuCtiOnS

inStRuCtiOnS PeRtaininG tO a RiSK OF FiRe, 

eleCtRiC ShOCK, OR injuRY tO PeRSOnS

WaRninG

 – When using tools, basic precautions should always be followed, including the following:

Set up Precautions

1. 

Gasoline fuel and fumes are flammable, 

and potentially explosive.

  Use proper fuel 

storage and handling procedures.  Do not store 

fuel or other flammable materials nearby.

2. 

Have multiple ABC class fire 

extinguishers nearby.

3. 

Operation of this equipment may create sparks 

that can start fires around dry vegetation.

 A 

spark arrestor may be required. The operator 

should contact local fire agencies for laws or 

regulations relating to fire prevention requirements.

4. 

Set up and use only on a flat, level, 

well-ventilated surface.

5. 

all connections and conduits from the 

Generator to the load must only be installed 

by trained and licensed electricians, and 

in compliance with all relevant local, state, 

and federal electrical codes and standards, 

and other regulations where applicable.

6. 

Connections for standby power to a building 

electrical system must be made by a qualified 

electrician.

 The connection must isolate the 

generator power from utility power, and must comply 

with all applicable laws and electrical codes. 

7. 

Wear anSi-approved safety goggles, 

heavy-duty work gloves, and dust 

mask/respirator during set up.

Содержание 68527

Страница 1: ...product s serial number in the back of the manual near the assembly diagram or month and year of purchase if product has no number Keep this manual and the receipt in a safe and dry place for future...

Страница 2: ...ons should always be followed including the following Set up Precautions 1 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store...

Страница 3: ...the equipment especially while it is operating 6 Keep all spectators at least six feet from the Engine during operation 7 Fire Hazard Do not fill gas tank while engine is running Do not operate if gas...

Страница 4: ...s such as tools away from exposed live electrical parts and connections to avoid sparking or arcing These events could ignite fumes or vapors 29 Stay alert watch what you are doing and use common sens...

Страница 5: ...irator during service 6 Maintain labels and nameplates on the equipment These carry important information If unreadable or missing contact Harbor Freight Tools for a replacement 7 Have the equipment s...

Страница 6: ...F 5W 30 at 32 F or below Capacity 6 Quart 6L Run Time 50 load 10 hr Operational Volume 70 dB Available accessories Wheel kit sold separately Item 68527 The emission control system for this Generator...

Страница 7: ...nt only to the AC Receptacle that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit breaker protects th...

Страница 8: ...tem 68531 sold separately can be used with this generator Grounding The Generator must be properly grounded before use Have the unit grounded by a qualified electrician if you are not qualified to do...

Страница 9: ...tarting engine To prevent FIRE do not start the engine while the smell of fuel hangs in the air Using the Generator Before Starting the Generator Engine Before starting the engine a Follow the Set Up...

Страница 10: ...ow the gasoline to flow into the Engine s carburetor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts N...

Страница 11: ...require the most wattage first b Connect inductive load appliances tools and equipment next Inductive loads are small hand tools and some small appliances c Connect any lights next d Voltage sensitive...

Страница 12: ...d To Calculate Wattage Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated...

Страница 13: ...Stopping the Engine in an Emergency To stop the engine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the generator and attached equipment Stopping the Engi...

Страница 14: ...to safely service the equipment or engine have a qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general...

Страница 15: ...revent FIRE do not start the engine while the smell of fuel hangs in the air Engine Oil Change CAUTION Oil is very hot during operation and can cause burns Wait for engine to cool before changing oil...

Страница 16: ...plug cap from end of plug Clean out debris from around spark plug 2 Using a spark plug wrench remove the spark plug 3 Inspect the spark plug If the electrode is oily clean it using a clean dry rag If...

Страница 17: ...cup next to the bowl and allow the fuel to drain from there as well c Open the fuel valve After all fuel has drained reinstall the drain bolt and sediment cup if equipped Tighten securely 3 Lubricatio...

Страница 18: ...e to RUN position Remove spark plug and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to CHOKE position 9 Replace Fuel Filter Ignition spark Related 1 S...

Страница 19: ...e to warm up prior to operating equipment Engine knocks 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fuel...

Страница 20: ...lt 3 55 Shroud 1 56 Shroud Cylinder Body 1 57 Shield Lower 1 58 Protector Oil 1 59 Bolt 4 60 Bolt 2 61 Bolt 1 62 Collar 1 63 Bolt 1 64 Carburetor Assy 1 65 Gasket Air Cleaner 1 66 Gasket Carburetor 1...

Страница 21: ...embly Power Supply 2 117 Protector Overcurrent 1 Part Description Qty 118 Protector Overcurrent 2 119 Terminal Subassembly Grounding 1 120 Socket Subassembly DC 1 121 Switch Subassembly 1 122 Case Pan...

Страница 22: ...40 45 45 46 46 10 6 7 1 9 9 9 8 8 9 11 7 6 4 61 55 58 59 63 62 59 59 59 60 60 57 56 47 48 48 49 49 50 50 51 51 42 43 5244 41 52 3637 77 80 81 82 83 84 84 78 79 26 95 123 115 118 118 119 120 121 116 1...

Страница 23: ...on your engine for the periods of time described below provided there has been no abuse neglect or improper maintenance of your engine Your emission control system may include parts such as the carbu...

Страница 24: ...arts which are not authorized by HFT b Improper installation adjustment or repair of the engine or of any warranted part unless performed by an authorized warranty center c Failure to follow recommend...

Отзывы: