For Pump technical questions, please call 1-800-444-3353.

For engine technical questions, please call 1-800-520-0882.

Sa
Fet

Y

O

Pe

R

ati

O

n

m

aintenan

C

e

Setu

P

16. 

Connect the Generator only to a load or 

electrical system (120 volt or 240 volt) that is 

compatible with the electrical characteristics 

and rated capacities of the Generator.

17. 

insulate all connections and disconnected wires.

18. 

Guard against electric shock.

  Prevent 

body contact with grounded surfaces such as 

pipes, radiators, ranges, and refrigerators.

19. 

Only use a suitable means of transport and 

lifting devices with sufficient weight bearing 

capacity when transporting the generator.

20. 

Secure the Generator on transport vehicles to 

prevent the tool from rolling, slipping, and tilting.

21. 

industrial applications must 

follow OSha requirements.

22. 

Do not leave the Generator unattended when it is 

running.

  Turn off the Generator (and remove safety 

keys, if available) before leaving the work area.

23. 

the Generator engine can produce high 

noise levels.

 Prolonged exposure to noise levels 

above 85 dBA is hazardous to hearing. Always 

wear ear protection when operating or working 

around the gas engine while it is operating.

24. 

Wear anSi-approved safety glasses  and 

hearing protection during use.

25. 

People with pacemakers should consult their 

physician(s) before use.

  Electromagnetic 

fields in close proximity to a heart pacemaker 

could cause pacemaker interference or 

pacemaker failure.  Caution is necessary when 

near the engine’s magneto or recoil starter.

26. 

use only accessories that are recommended 

by harbor Freight tools for your model.  

Accessories that may be suitable for one 

piece of equipment may become hazardous 

when used on another piece of equipment.

27. 

Do not operate in explosive atmospheres, 

such as in the presence of flammable 

liquids, gases, or dust. 

 Gasoline-powered 

engines may ignite the dust or fumes.

28. 

Keep grounded conductive objects, such as 

tools, away from exposed, live electrical parts 

and connections to avoid sparking or arcing.

  

These events could ignite fumes or vapors.

29. 

Stay alert, watch what you are doing 

and use common sense when operating 

this piece of equipment.

  Do not use this 

piece of equipment while tired or under the 

influence of drugs, alcohol or medication.

30. 

Dress properly. 

 Do not wear loose clothing or 

jewelry.  Keep hair, clothing and gloves away 

from moving parts.  Loose clothes, jewelry or 

long hair can be caught in moving parts.

31. 

Parts, especially exhaust system components, 

get very hot during use.

  Stay clear of hot parts.

32. 

Do not cover the generator or its 

engine during operation.

33. 

Keep the generator, its engine, and 

surrounding area clean at all times.

34. 

use the generator, accessories, etc., in 

accordance with these instructions and in 

the manner intended for the particular type of 

equipment, taking into account the working 

conditions and the work to be performed.  

Use 

of the equipment for operations different from those 

intended could result in a hazardous situation.

35. 

Do not operate the generator with known 

leaks in the engine’s fuel system.

36. 

this product contains or, when used, 

produces a chemical known to the State of 

California to cause cancer and birth defects 

or other reproductive harm.

  (California 

Health & Safety Code § 25249.5, 

et seq.

)

37. 

When spills of fuel or oil occur, they must 

be cleaned up immediately.

  Dispose of fluids 

and cleaning materials as per any local, state, or 

federal codes and regulations.  Store oil rags in 

a bottom-ventilated, covered, metal container.

38. 

Keep hands and feet away from moving parts.

  Do 

not reach over or across generator while operating.

39. 

Before use, check for misalignment or binding 

of moving parts, breakage of parts, and any 

other condition that may affect the generator’s 

operation.

  

if damaged, have the generator 

serviced before using.

  Many accidents are 

caused by poorly maintained equipment.

40. 

use the correct generator for the 

application. 

 Do not modify the generator or 

its engine, and do not use the generator for 

a purpose for which it is not intended.

Operating Precautions (cont.)

Содержание 68527

Страница 1: ...product s serial number in the back of the manual near the assembly diagram or month and year of purchase if product has no number Keep this manual and the receipt in a safe and dry place for future...

Страница 2: ...ons should always be followed including the following Set up Precautions 1 Gasoline fuel and fumes are flammable and potentially explosive Use proper fuel storage and handling procedures Do not store...

Страница 3: ...the equipment especially while it is operating 6 Keep all spectators at least six feet from the Engine during operation 7 Fire Hazard Do not fill gas tank while engine is running Do not operate if gas...

Страница 4: ...s such as tools away from exposed live electrical parts and connections to avoid sparking or arcing These events could ignite fumes or vapors 29 Stay alert watch what you are doing and use common sens...

Страница 5: ...irator during service 6 Maintain labels and nameplates on the equipment These carry important information If unreadable or missing contact Harbor Freight Tools for a replacement 7 Have the equipment s...

Страница 6: ...F 5W 30 at 32 F or below Capacity 6 Quart 6L Run Time 50 load 10 hr Operational Volume 70 dB Available accessories Wheel kit sold separately Item 68527 The emission control system for this Generator...

Страница 7: ...nt only to the AC Receptacle that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used 3 ON OFF Circuit Breakers The circuit breaker protects th...

Страница 8: ...tem 68531 sold separately can be used with this generator Grounding The Generator must be properly grounded before use Have the unit grounded by a qualified electrician if you are not qualified to do...

Страница 9: ...tarting engine To prevent FIRE do not start the engine while the smell of fuel hangs in the air Using the Generator Before Starting the Generator Engine Before starting the engine a Follow the Set Up...

Страница 10: ...ow the gasoline to flow into the Engine s carburetor Then pull the Starter Handle gently until resistance is felt Allow Cable to retract fully and then pull it quickly Repeat until the engine starts N...

Страница 11: ...require the most wattage first b Connect inductive load appliances tools and equipment next Inductive loads are small hand tools and some small appliances c Connect any lights next d Voltage sensitive...

Страница 12: ...d To Calculate Wattage Volts and amps can be multiplied together to get watts volts x amps watts To Calculate Additional Start Up Watts If They Are Not Listed For equipment with a motor Use the rated...

Страница 13: ...Stopping the Engine in an Emergency To stop the engine in an emergency turn the Engine Switch off NOTICE Generator shut off under load may damage the generator and attached equipment Stopping the Engi...

Страница 14: ...to safely service the equipment or engine have a qualified technician service the equipment instead Cleaning Maintenance and Lubrication Note This maintenance schedule is intended solely as a general...

Страница 15: ...revent FIRE do not start the engine while the smell of fuel hangs in the air Engine Oil Change CAUTION Oil is very hot during operation and can cause burns Wait for engine to cool before changing oil...

Страница 16: ...plug cap from end of plug Clean out debris from around spark plug 2 Using a spark plug wrench remove the spark plug 3 Inspect the spark plug If the electrode is oily clean it using a clean dry rag If...

Страница 17: ...cup next to the bowl and allow the fuel to drain from there as well c Open the fuel valve After all fuel has drained reinstall the drain bolt and sediment cup if equipped Tighten securely 3 Lubricatio...

Страница 18: ...e to RUN position Remove spark plug and pull the start handle several times to air out the chamber Reinstall spark plug and set Choke to CHOKE position 9 Replace Fuel Filter Ignition spark Related 1 S...

Страница 19: ...e to warm up prior to operating equipment Engine knocks 1 Old or low quality gasoline 2 Engine overloaded 3 Incorrect spark timing deposit buildup worn engine or other mechanical problems 1 Fill fuel...

Страница 20: ...lt 3 55 Shroud 1 56 Shroud Cylinder Body 1 57 Shield Lower 1 58 Protector Oil 1 59 Bolt 4 60 Bolt 2 61 Bolt 1 62 Collar 1 63 Bolt 1 64 Carburetor Assy 1 65 Gasket Air Cleaner 1 66 Gasket Carburetor 1...

Страница 21: ...embly Power Supply 2 117 Protector Overcurrent 1 Part Description Qty 118 Protector Overcurrent 2 119 Terminal Subassembly Grounding 1 120 Socket Subassembly DC 1 121 Switch Subassembly 1 122 Case Pan...

Страница 22: ...40 45 45 46 46 10 6 7 1 9 9 9 8 8 9 11 7 6 4 61 55 58 59 63 62 59 59 59 60 60 57 56 47 48 48 49 49 50 50 51 51 42 43 5244 41 52 3637 77 80 81 82 83 84 84 78 79 26 95 123 115 118 118 119 120 121 116 1...

Страница 23: ...on your engine for the periods of time described below provided there has been no abuse neglect or improper maintenance of your engine Your emission control system may include parts such as the carbu...

Страница 24: ...arts which are not authorized by HFT b Improper installation adjustment or repair of the engine or of any warranted part unless performed by an authorized warranty center c Failure to follow recommend...

Отзывы: