Section Four - Checking EFX Operation
This section provides you with a quick method of checking EFX operation. Check the operation
of the EFX at the end of most maintenance procedures.
Procedure
1.
Plug the power cord into the wall outlet and set the on/off switch in the “on” position.
2.
With the
PRECOR EFX
banner displayed, press
QUICK START
.
3.
Select Resistance Level 1.
4.
Operate the EFX for 4–5 minutes. As you operate the EFX, concentrate on the operating
sounds made by the unit. Be on the alert for unusual rubbing, hitting, grinding, or squeaking
noises.
5.
If the EFX makes unusual noises or the electronic display does not change appropriately,
troubleshoot per section 6.4.
6.
Press the
RESISTANCE
S
key until you reach Resistance Level 8. Operate the EFX for
another 2–3 minutes.
7.
If the EFX resistance does not change or the operation of the EFX feels inconsistent
compared with Resistance Level 1, troubleshoot per section 6.4.
8.
Press the
RESISTANCE
S
key until you reach Resistance Level 16. Operate the EFX for
another 2–3 minutes.
9.
If the resistance of the EFX does not change or the EFX operation feels inconsistent with
Resistance Levels 1 and 8, troubleshoot per Procedure 6.4.
10. Check the LED’s mounted on the upper PCA and the function keys displayed on the
electronic console by performing Procedure 2.1.
11. Turn off the EFX with the on/off switch, then unplug the power cord from the wall outlet.
Содержание EFX EFX 5.23