C100i Adaptive Motion Trainer
Page 35
Procedure 7.2 - Replacing the Lower PCA
1.
Remove the right side cover.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
2.
Attach the wrist strap to your arm, then connect the ground wire of the wrist strap to the
C100i frame.
3.
Disconnect the battery, 3 Phase Gen and load wires from the lower PCA.
4.
Remove the screw from the upper right corner the lower PCA, see Diagram 7.2.
Diagram 7.2 - Lower PCA
5.
Unsnap the lower PCA from its mounting bracket.
6.
Position the replacement lower PCA at its mounting position and snap it into its
mounting bracket. Fasten it with the screw removed in step 4.
7.
Reconnect the lower PCA wires as follows. The battery wires are polarized to prevent
them from being connected incorrectly. Connect the black wire to the battery terminal
nearest to the edge of the lower PCA and the red wire to the remaining battery terminal
of the lower PCA. Reconnect the 3 Phase Gen wires to the terminals shown in Diagram
7.2, the wires may be connected in any order. Reconnect the load wires to the
terminals shown in Diagram 7.2, the wires may be connected in any order.
Mounting Screw
3 Phase Gen
Load
Battery
Stride Sensor
(RJ11)
Data Cable
(RJ45)