Procedure 6.1 - Troubleshooting Interconnect Cable
Anti-static kits can be ordered from Precor (part number 20024-101).
Troubleshooting the Upper Interconnect Cable
1.
Remove the display’s rear cover.
2.
Remove the right side cover.
3.
Disconnect the interconnect cable from the upper PCA and the lower PCA.
4.
External of the upper column, connect a replacement interconnect cable to the lower
PCA and the upper PCA.
5.
Check operation as described in Section 4. If the unit works properly, replace the
interconnect cable as described in Procedure 7.3.
6.
If you have performed all of the procedures above and have been unable to correct the
problem, call Precor customer support.