Page 24
9.
If the lower data cable corrects the problem, replace the cable per Procedure 7.4. If the
lower data cable does not correct the problem, re-connect the original lower data cable to
the lower PCA and mid-point connector and continue with step 10.
10. Remove the cover from the rear of the display. Disconnect the upper data cable from the
mid-point connector and the upper PCA. See Diagram 6.2. Substitute a known good data
cable from the upper PCA to the mid-point connector. It is not necessary to route the test
data cable through the frame tube, for convenience route it externally.
Diagram 6.2 - Upper Display Cable
11. If the upper data cable corrects the problem, replace the cable per Procedure 7.4. If the
upper data cable does not correct the problem, re-connect the original upper data cable to
the mid-point connector and the upper PCA and continue with step 10.
12. Carefully, set the outrigger tube in its mounting position and fasten it with the bolts and
clamp removed in step 3.
13. Replace the covers removed in step 2.
14. If you have performed all of the procedures above and have been unable to correct the
problem, call Precor customer service.
Upper Data Cable
Display Face
Mounting Clip
Heart Rate PCA