Rev 8/2014
PrecisionTemp, Inc • 11 Sunnybrook Drive • Cincinnati, Ohio, 45237 • 1-800-934-9690 •
fax 513-641-0733 61
SB-20
Testing the PT-56
Model:
PT-56
Other service documents required:
Thermistor Reading – T-mid/T-out
Tools Required:
Precision screwdriver
Gas supply pressure (to regulator) = 7.0 – 10.5 wci for natural gas (NG)
11.0 – 14.0 wci for propane (LPG)
Water supply pressure to booster = 25 psig normal (60 psig maximum)
Instrumentation:
T-mid
Circuit board thermistor reading (yellow test connector)
T-out
Circuit board thermistor reading (orange test connector)
T-set
Circuit board thermistor reading (blue test connector)
Test Data :
1.
Turn power ON and verify that the green LED flashes.
2.
Is the red LED flashing? If yes, refer to Section 5 in trouble-shooting manual.
3.
Verify unit lights off at ignition burn (0.19 – 0.35 wci) and ramps to maximum
burn (3.15 – 3.80 wci).
4.
While the unit is heating to the stabilization temperature set the T-set as
described in the owner’s manual. Find the booster output temperature in the
table below and then go to the column that specifies the T-set voltage. Refer to
section 4.11 ‘Thermistor Checkout – T-mid/T-out’ for a description on how to
read T-set:
Outlet Temperature
Stabilization
Temperature
T_set Voltage, vdc
140
158 (1.27 vdc)
1.75
150
168 (1.10 vdc)
2.38
160
178 (0.95 vdc)
3.00
170
188 (0.82 vdc)
3.62
180
198 (0.71 vdc)
4.25
5.
Verify that the burner modulates down as the stabilization temperature is
reached. The minimum burn is 0.90 – 1.50 wci).
6.
Verify that the unit cycles ON and OFF at the stabilization temperature to
control and hold the temperature.
7.
Let the unit reach stabilization. When burner is OFF and right before a re-light
read T-out voltage. Refer to Section 4.1 ‘Thermistor Checkout – T-mid/T-out’
for a description on how to read the thermistors. This should be within
±
±
±
±
0.02 vdc (
±
±
±
±
2
°°°°
F) of the stabilization temperature listed in the table above.
8.
Run several dishwasher cycles that the PT56 responds by igniting to maintain
temperature.
9.
Fail T-mid thermistor by disconnecting the 2-pin connector. Verify that gas flow
is shutoff and the maintenance code is one on the red LED.
10.
Verify that the unit does not leak water.
Содержание PT-200FT
Страница 11: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 11...
Страница 13: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 13...
Страница 14: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 14...
Страница 15: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 15...
Страница 16: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 16...
Страница 17: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 17...
Страница 18: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 18...
Страница 19: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 19...
Страница 23: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 23...
Страница 24: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 24...
Страница 25: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 25...
Страница 26: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 26...
Страница 27: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 27...
Страница 28: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 28...
Страница 29: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 29...
Страница 30: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 30...
Страница 31: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 31...
Страница 32: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 32...
Страница 33: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 33...
Страница 34: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 34...
Страница 42: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 42...
Страница 58: ...Rev 8 2014 PrecisionTemp Inc 11 Sunnybrook Drive Cincinnati Ohio 45237 1 800 934 9690 fax 513 641 0733 58...