background image

Today's IAQ Challenges

The effort to increase performance and efficiency of
buildings  has resulted in tighter construction and
reduced air infiltration.  Airborne particulate and gas
phase contaminants released from  paint, carpeting,
wallpaper, insulation, copy machines, and cleaning
agents become trapped in the work environment.

A typical ventilation system recirculates 80-90% of the
total air volume in the building, and introduces 10-20%
outside (make-up) air to the recirculated air, in order to
dilute the airborne contaminants and reduce stale-
ness.  However, make-up air often introduces new
pollutants to the building, such as diesel and gasoline
engine exhaust, mold, pollen, dust, offensive odors
and other common outdoor pollutants.

The key to providing healthy indoor air is reducing the
levels of airborne particulate and gas phase contami-
nants.   A successful ventilation system reduces the
levels of contaminants through high efficiency filtration
and gas phase control, while at the same time, reduc-
ing maintenance, upkeep, and operating costs.

Filtration System Considerations

PurePac's particle collection efficiency is continuous
and not highly dependent on particle size or filter load-
ing, therefore actual efficiencies of 90-95% and high-
er can be achieved at an economical operating cost.

PurePac is available with optional TechSorb HMZD
impregnated bonded carbon panels for gas phase
contaminant and odor control.  The rigid panels elimi-
nate air by-pass, channeling and settling, which are
typical with conventional loose granular carbon filters.
The disposable HMZD panels also offer clean, easy,
removal and replacement.

The operating cost to move ventilation air through a fil-
tration system is directly related to the filter is resist-
ance.  PurePac's low and constant 0.25î w.g. resist-
ance results in reduced fan horsepower and a signifi-
cant energy savings compared to conventional filtra-
tion.  Since PurePac's efficiency is instant and contin-
uous, fouling of heating and cooling coils is reduced,
resulting in higher performance and reduced operat-
ing cost of the system.

PurePac incorporates a permanent self-cleaning sys-
tem, eliminating the replacement and labor cost of
buying, changing, and disposing of filters.  A life cycle
cost analysis almost always shows that PurePac's
performance and reliability can be justified.

Today’s Solution

PurePac is designed to work in conjunction with a
building’s air handling units and ventilation systems,
delivering the specified level of efficiency, continuous-
ly and reliably.  

High reliability, optimum performance, and low operat-
ing cost make PurePac the IDEAL SOLUTION for
today’s indoor air quality challenges.

Performance

PurePac uses a 2-stage electronic collector for partic-
ulate control.  A high-density, low power first stage
charges each particle.  The charged particles then
travel downstream into the second stage where they
are repelled from the air stream, captured, and
retained on collector plates.

The electronic collector uses an airfoil design that
eliminates air-bypass, so all of the HVAC system air
and airborne particulate pass directly through the

Flanders Precisionaire - Foremost in Air Filtration            

Engineered Products: 1-800-637-2803     Replacement Products: 1-800-347-2220

Содержание PB1900-0604

Страница 1: ...oor air Configuration PurePac Side Access units are available in sizes ranging from 3 000 to 30 000 cfm Housings are 16 gauge galvanealed steel continuously welded primed and painted Pre and post mist eliminators electronic collectors and built in cleaning system are factory assembled into the housing PLC control and detergent dispenser are supplied as separate compo nents PurePac front access uni...

Страница 2: ...onal loose granular carbon filters The disposable HMZD panels also offer clean easy removal and replacement The operating cost to move ventilation air through a fil tration system is directly related to the filter is resist ance PurePac s low and constant 0 25î w g resist ance results in reduced fan horsepower and a signifi cant energy savings compared to conventional filtra tion Since PurePac s e...

Страница 3: ...g capacities and reduced system footprint This translates into extra available floor space up to 30 in some instances PurePac s low resistance to airflow results in reduced fan horsepower and fan energy cost Over a period of time this reduction amounts to significant savings in energy costs Since PurePac uses wash in place electronic collectors replacement filter cost disposal cost and labor cost ...

Страница 4: ...with the following standard accessories Wash water strainer 1 each Ball valve 1 each Backflow preventer 1 each Solenoid valve 1 each Access door electrical interlock pilot light 2 each Detergent 55 gal Utilities Electrical Standard 120 Vac 1 ph 60 Hz Optional 208 230 460 Vac 1 ph 50 60 Hz Wash Water See Selection Table gpm 40 psig System Drain Sized according to applicable codes to handle water an...

Страница 5: ...5 90 85 H W gpm gal lb FA 0604 22 8 10 000 12 500 14 000 77 3 8 50 3 8 28 8 1 4 1 025 FA 0605 28 32 12 500 15 500 17 500 77 3 8 61 3 16 36 1 8 1 160 FA 0606 33 84 15 000 18 000 21 000 77 3 8 72 43 2 2 2 1 295 FA 0804 30 4 13 500 16 500 18 500 102 5 8 50 3 8 38 4 1 9 1 250 FA 0805 37 76 16 500 20 500 23 000 102 5 8 61 3 16 48 2 4 1 540 FA 0806 45 12 20 000 24 500 27 500 102 5 8 72 57 6 2 9 1 740 FA...

Страница 6: ...minators electronic collectors integral wash system and electrically interlocked access door Options PurePac Model SA is available with TechSorb HMZD bonded activated carbon panels for gas phase control The TechSorb is contained in a sepa rate cabinet that conveniently bolts to the exhaust side of the Model SA cabinet The panels are arranged in a V Bank configuration using fully gasketed tracks to...

Страница 7: ...6 000 7 000 40 1 4 76 31 1 2 14 4 0 7 785 SA 0403 11 3 5 000 6 000 7 000 64 1 8 41 7 8 55 3 8 14 4 0 7 710 SA 0404 15 2 6 500 8 000 9 500 64 1 8 54 3 8 55 3 8 19 2 1 810 SA 0405 18 9 8 500 10 000 11 500 64 1 8 65 1 8 55 3 8 24 1 2 930 SA 0406 22 6 10 000 12 000 14 000 64 1 8 76 55 3 8 28 8 1 4 1 110 SA 0407 26 4 11 500 14 500 16 500 64 1 8 88 5 8 55 3 8 33 6 1 7 1 225 SA 0408 30 13 000 16 000 18 5...

Страница 8: ...g System Water detergent washing system shall be high pressure low volume type Detergent wash and rinse water shall be applied by oscillating copper manifolds containing brass spray nozzles located on both the air entering and air leaving side of each module tier Complete effective washing of all ion izing collector cell surfaces and all appurtenances shall be provided Drive motors used to oscilla...

Отзывы: