Precision Medical 1MFA3001 Скачать руководство пользователя страница 7

REPLACEMENT PARTS

Description

Model No.

6MFA1001

0-200 cc

OXYGEN

50 PSI

Model No.

4MFA1001

0-1 lpm

OXYGEN

50 PSI

Model No.

1MFA3001

0-3 lpm

OXYGEN

50 PSI

1

Spring

1575

1575

1575

2

Washer

1787

1787

1787

3

Housing

1143

1143

1143

4

Tetraseal™

1123

1123

1123

5

Flow Tube Kit

503213

503214

503215

6

Float Ball 

1576

1576

1576

7

Body assembly

1891

1897

502053

8

Knob

1007

1007

1007

International parts specifications and specific ratings are available 
upon request.
International flowmeters are calibrated per specifications on 
flowtube.

DECLARATION OF CONFORMITY

Manufacturer: 

Precision Medical, Inc.

 

300 Held drive, Northampton, Pa 18067, USa 

CONTaCT: Quality Manager 

 

Phone: 610-262-6090

authorized European Representative: 

Emergo Europe

 

Molenstraat 15

 

2513 BH, The Hague

 

The Netherlands

Product: 

Flowmeters

Model(s): 

1MFa

Mdd Class: 

IIb

Classification criteria: 

Clause 3.2 Rule 11 of annex IX of Mdd

as delivered, the object of the declaration described above is in conformity with the requirements of Mdd 93/42/

EEC annex II.3 and the following documents:

document 

Title 

Edition

BS EN 13220 

Flow Metering devices for Connection to Terminal Units of Medical Gas 

1999

 

Pipeline Systems

ISO 14971 

Medical devices - application of risk management to Medical  

2000+a:1:2003

devices, 2nd Edition

EN 980 

Graphical Symbols for Use in the labeling of Medical devices 

2003

BS EN 1041 

Information supplied by the Manufacturer with Medical devices 

1998

EN ISO 15001 

anaesthetic and Respiratory Equipment - Compatibility with Oxygen 

2003

Notified Body: 

TÜV Rheinland Products Safety GmbH 

EC Certificate No.: 

Hd 60019110 0001

Содержание 1MFA3001

Страница 1: ...tative EMERGO EUROPE INC Molenstraat 15 2513 BH The Hague Netherlands SAVE THESE INSTRUCTIONS CAUTION Federal USA law restricts this device to sale by or on the order of a physician 300 Held Drive Tel...

Страница 2: ...Flowmeter This is provided for your safety and to prevent damage to the Flowmeter If you do not understand this manual DO NOT USE the Flowmeter and contact your Provider safety information warnings an...

Страница 3: ...xplosive substances vapors or atmosphere DO NOT smoke in an area where oxygen is being administered CAUTION This Flowmeter must be operated with the Flow Tube in a vertical upright position Only perso...

Страница 4: ...lpm 20 40 lpm Transport Storage Requirements 40 F 40 C to 140 60 C Restricted Max Flush Flow Note Storage Transport outside the specified range may cause damage to the flowmeter The effect on accuracy...

Страница 5: ...ow Tube NOTE If the Float is not resting at the bottom of the Flow Tube the product is leaking consult the Troubleshooting Guide 4 Adjust Flow To increase Turn Knob counterclockwise To decrease Turn K...

Страница 6: ...and water 3 Wipe dry with a clean cloth Troubleshooting If the Flowmeter fails to function consult the Troubleshooting Guide below If problem cannot be corrected consult your Provider or Precision Med...

Страница 7: ...n Representative Emergo Europe Molenstraat 15 2513 BH The Hague The Netherlands Product Flowmeters Model s 1MFA MDD Class IIb Classification criteria Clause 3 2 Rule 11 of Annex IX of MDD As delivered...

Страница 8: ...l Inc or any retailers are not authorized to make oral warranties about the merchandise described in this contract and any such statements shall not be relied upon and are not part of the contract for...

Отзывы: