PD6700 Field-Mount Loop-Powered Process Meter 

Instruction Manual 

 

12

 

Setting Numeric Values 

The numeric values are set using the 

Right 

and 

Up

 

arrow buttons. Press 

Right 

arrow to select next digit 

and 

Up 

arrow to increment digit. 

The digit being changed blinks. 
Press the 

Enter 

button, at any time, to accept a 

setting or 

MENU

 button to exit without saving 

changes. 
The decimal point is set using the 

Right

 or 

Up 

arrow 

button in the 

Setup-decimal point

 menu. 

 

 

Setting the Decimal Point (

Dec.Pt

Decimal point may be set with up to four decimal 
places or with no decimal point. 
Pressing the 

Right

 arrow moves the decimal point 

one place to the right until no decimal point is 
displayed. Pressing the 

Up

 arrow moves the decimal 

point one place to the left. 

 

 

Programming the Meter (

Prog

The meter may either be scaled (

SCALe

) without 

applying an input or calibrated (

Cal

) by applying an 

input. The meter comes factory calibrated to NIST 
standards, so for initial setup, it is recommended to 
use the (

SCALe

) function. The Program menu contains 

the Scale (

SCALe

) and the Calibrate (

Cal

) menus. 

Process inputs may be scaled or calibrated to any 
display within the range of the meter. 
 

 

 

Note: The Scale and Calibrate functions are exclusive 
of each other. The meter uses the last function 
programmed. Only one of these methods can be 
employed at a time. The Scale and Calibrate 
functions can use up to 32 points (default is 2). The 
number of points should be set in the Advanced 
Features menu under the Multi-Point Linearization

 

(

lnear

)

 menu selection prior to scaling and calibration 

of the meter, see Advanced Features Menu, page 15. 

Scaling the Meter (

SCale

The 4-20 mA input can be scaled to display the  
process in engineering units. 
A signal source is not needed to scale the meter; 
simply program the inputs and corresponding display 
values. 

 

 

 

For instructions on how to program numeric  
values see 

Setting Numeric Values

, page 

12

.

 

 

 

 

Содержание vantageview Safe Touch PD6700

Страница 1: ...2 mm 7 Alphanumeric Characters Lower Display Display Mountable at 0 90 180 270 SafeTouchTM Through Window Button Programming HART Protocol Transparent Loop or External DC Powered Backlight Standard O...

Страница 2: ...and Terms Conditions on www predig com for complete details 2020 Precision Digital Corporation All rights reserved Introduction The PD6700 is a rugged field mount loop powered NEMA 4X meter fully feat...

Страница 3: ...aL 13 Setting the Tag Display tag 13 Setting Up the Password PASSWRD 14 Locking the Meter 14 Setting Up the Meter SETUP 14 Making Changes to a Password Protected Meter 14 Disabling Password Protection...

Страница 4: ...ures Figure 1 Enclosure Dimensions Front View 6 Figure 2 Enclosure Dimensions Side Cross Section View 6 Figure 3 Connector Board 7 Figure 4 Connections without Backlight 8 Figure 5 Connections with Lo...

Страница 5: ...mental Operating temperature range 40 to 75 C Storage temperature range 40 to 75 C Relative humidity 0 to 90 non condensing Connections Screw terminals accept 12 to 22 AWG wire Enclosure NEMA 4X IP65...

Страница 6: ...and set the display module aside Unpacking Remove the meter from box Inspect the packaging and contents for damage Report damages if any to the carrier If any part is missing or the meter malfunctions...

Страница 7: ...gative terminal when using the installed loop powered backlight or ground negative when powering backlight from external supply Refer to Figure 3 for terminal positions Observe all safety regulations...

Страница 8: ...ections without Backlight Figure 5 Connections with Loop Powered Backlight Loop powered backlight brightness will increase as the input signal current increases If constant backlight brightness is des...

Страница 9: ...window directly over the marked button area When the cover is removed the four mechanical buttons located next to the sensors are used The sensors are disabled when a mechanical button is pressed and...

Страница 10: ...ess the Advanced features of the meter Right Reset Button Press the Right arrow button to move to the next digit or decimal position during programming Up Display Button Press the Up arrow button to s...

Страница 11: ...he Tag Units Menu ON Tag On Enable Tag Units OFF Tag Off Disable Tag Units PASSWRD Password Enter the Password menu UNLOCKD Unlocked Program password to lock meter LOCKED Locked Enter password to unlo...

Страница 12: ...brated Cal by applying an input The meter comes factory calibrated to NIST standards so for initial setup it is recommended to use the SCALe function The Program menu contains the Scale SCALe and the...

Страница 13: ...s Enter to accept After completing calibration the save display will need to be acknowledged using the Enter key before calibration will take effect Minimum Input Span The minimum input span is the mi...

Страница 14: ...password to gain access to the menu After exiting the programming mode the meter returns to its password protected condition Disabling Password Protection To disable the password protection access the...

Страница 15: ...Set Point Program set point ReseT Reset Point Program reset point Funct Function Enter advanced function menu Lnear Linear Set linear scaling Squar Square Root Set square root extraction Prog E Progr...

Страница 16: ...lection FUNCTN The Advanced Function menu is used to select the advanced function to be applied to the input linear square root or programmable exponent The multi point linearization is part of the li...

Страница 17: ...effect However you may move past this selection using the Up arrow key if you need to go back and correct and earlier entry Once confident in the entries you must navigate back to the Save menu screen...

Страница 18: ...h HI or off OFF The higher the filter setting the longer the averaging time and so the longer the display may take to find its final value The filter contains a noise filter bypass feature so that whi...

Страница 19: ...seconds The meter will return to display the actual reading Reset Meter to Factory Defaults When the parameters have been changed in a way that is difficult to determine what s happening it might be b...

Страница 20: ...to exit Max Min display readings Display response is too slow Check filter setting to see if it can be lowered to LO or OFF If the display locks up or the meter does not respond at all Perform hard re...

Страница 21: ...on or increment digit Cycle through maximum minimum and mA display mode ENTER Accept selection value and move to next selection Acknowledge alarms To enter the Advanced Features Menu hold the Menu but...

Страница 22: ...990 www predig com LIM6700_D SFT049 Ver 1 200 up 07 20 Contact Precision Digital Technical Support Call 800 610 5239 or 508 655 7300 Fax 508 655 8990 Email support predig com Sales Support Call 800 34...

Отзывы: