P
RO
V
U
™ PD6088/PD6089 Modbus
®
Scanner
Instruction Manual
49
Advanced Features Menu & Display Messages
Display
Parameter
Action/Setting
Inp 1
Input 1
Scale input 1 signal or
program input 1 value
Dis 1
Display 1
Program display 1 value
Inp 2
Input 2
Scale input 2 signal or
program input 2 value
(up to 32 points for PV1
& PV2)
Dis 2
Display 2
Program display 2 value
(up to 32 points for PV1
& PV2)
square
Square Root
Enter
Square Root
menu
Prog e
Programmable
Exponent
Enter
Programmable
Exponent
menu
1.5000
Programmable
Exponent
Value
Enter the
Programmable
Exponent Value
rht
Round
Horizontal
Tank
Enter
Round
Horizontal Tank
menu
Inch
Inch
Enter to calculate tank
values in Inches
cnm
Centimeters
Enter to calculate tank
values in Centimeters
dianmr
Diameter
Enter tank diameter
Length
Length
Enter tank length
nmath
Math
Enter
Math
menu
Ch C1
*
Channel C1
*Enter
Math Channel
C1-C4
menu
Opertn
Operation
Enter
Math Operation
menu
Const
Constant
Enter
Math Constant
menu
Adder
Adder
Enter
Adder Value
FACtr
Factor
Enter
Factor Value
sunm
Sum
Math Function
Sum
dif
Difference
Math Function
Difference
difabs
Absolute
Difference
Math Function
Absolute Difference
aVg
Average
Math Function
Average
nmulti
Multiply
Math Function
Multiply
diVide
Divide
Math Function
Divide
Hi-pV
Max
Math Function
Maximum of all
selected PVs
Lo-pV
Min
Math Function
Minimum of all
selected PVs
dra
uw
Draw
Math Function
Draw
uw
aVg
Weighted
Average
Math Function
Weighted Average
ratio
Ratio
Math Function
Ratio
Concen
Concentration
Math Function
Concentration
nmath2
Math2
Resultant Math
Channel
Math operation applied
to other math channels
(e.g. C3 = C1/C2)
sunm
Sum
Math2 Function
Sum
dif
Difference
Math2 Function
Difference
Advanced Features Menu & Display Messages
Display
Parameter
Action/Setting
difabs
Absolute
Difference
Math2 Function
Absolute Difference
aVg
Average
Math2 Function
Average
nmulti
Multiply
Math2 Function
Multiply
diVide
Divide
Math2 Function
Divide
Cutoff
Cutoff
Enter
Low Flow Cutoff
menu
PV 1
PV 1 Cutoff
Program Cutoff Value
for PV 1
PV 2
PV 2 Cutoff
Program Cutoff Value
for PV 2
aoutPr
Analog Output
Program
Enter
Analog Output
Programmable
parameters menu
Aout 1
*
Analog
Output 1-3
*Analog Output 1-3
(If Installed)
SourCE
Analog Output
Data Source
Enter Analog Output
Data
Source
menu
PV 1
*
Source PV
*Select
PV
for Analog
Output Data Source
Ch C1
*
Source Math
Channel
*Select
C1-4
for
Analog Output Data
Source
Set 1
*
Set Point 1-8
*Select Set Points 1-8
break
Communica-
tions Break
Enter the Analog
Output value when
Communications Break
is detected
ignore
Ignore Break
Ignore Break
force
Force Break
Force Break
CALib
Calibration
Enter the Analog
Output
Calibration
menu
nmAx
Maximum
Select
Maximum
value
for all Analog Outputs
nmin
Minimum
Select
Minimum
value
for all Analog Outputs
O-rang
Overrange
Enter the Analog
Output value for an
Overrange
condition
u-rang
Underrange
Enter the Analog
Output value for an
Underrange
condition
user
User
Enter the
User
menu
for assigning function
keys and digital I/O
F1
*
F1-4
*F1-F4 Function Keys
preV
Previous
Previous PV
next
Next
Next PV
SCAn
Scan
Scan or pause scan
Ack
Acknowledge
Acknowledge relays
reset
Reset
Enter
Reset
menu
Rst Hi
Reset Max
Reset Maximum
Rst Lo
Reset Min
Reset Minimum
Rst HL
Reset
Max-Min
Reset Maximum &
Minimum
relay
Relay
Relay menu
Set 1
*
Set Points 1-8
Set Points 1-8
Rly d
Relay Disable
Relay Disable
(all relays)