Helios Large Display Temperature Meter 

Instruction Manual 

PD2-7000 

 

 

 

 

Precision Digital Corporation

 

 

 

 

Temperature 

 

 

 

  Large 1.80" Digits 

  Dual-Line 6-Digit Display  

  Readable from up to 100 Feet (30 Meters) Away 

  Superluminous Sunlight Readable Display 

  NEMA 4X, IP65 Rated Field Mountable Enclosure 

  Operating Temperature Range of -20 to 65°C (-4 to 150°F) 

  J, K, T, E, R, S, B, N, C Thermocouples 

  100 or 1000 Ω Platinum, 10 Ω Copper, 120 Ω Nickel RTDs 

  1° or 0.1° Resolution 

  Averages up to 10 RTD Sensors 

  Automatic Cold Junction Compensation 

  Input Power Options Include 85-265 VAC or 12-24 VDC 

  Programmable Display & Function Keys 

  2 or 4  Isolated 4-20 mA Output Options 

  Onboard USB & RS-485 Serial Communication Options 

  Modbus

®

 RTU Communication Protocol Standard 

  Program the Meter from a PC with onboard USB and MeterView Pro 

USB Install

www.

.com

[email protected]

1.800.561.8187

Содержание Helios PD2-7000 Series

Страница 1: ...C 4 to 150 F J K T E R S B N C Thermocouples 100 or 1000 Platinum 10 Copper 120 Nickel RTDs 1 or 0 1 Resolution Averages up to 10 RTD Sensors Automatic Cold Junction Compensation Input Power Options...

Страница 2: ...injury or property loss Anyone using this product for such applications does so at their own risk Precision Digital Corporation shall not be held liable for damages resulting from such improper use L...

Страница 3: ...on 31 Programming Time Delay 31 Relay Action for Loss of 4 20 mA Input Loop Break 31 Relay and Alarm Operation Diagrams 31 High Alarm Operation Set Reset 31 Low Alarm Operation Set Reset 31 High Alarm...

Страница 4: ...Connections 19 Figure 24 Acknowledge Relays with Function Key or Digital Input 36 Introduction The Helios PD2 7000 is a multi purpose easy to use large display digital temperature meter It features l...

Страница 5: ...l inputs PC and MeterView Pro software or Modbus registers Noise Filter Programmable from 2 to 199 0 will disable filter Filter Bypass Programmable from 0 1 to 99 9 of calibrated span Recalibration Al...

Страница 6: ...r allows the user to apply an offset value to the temperature being displayed Input Impedance Greater than 100 k Sensor Break Detection Open TC or RTD sensor indicated by display flashing oPEn relays...

Страница 7: ...8 A C max from 40 to 0 C ambient Note Analog output drift is separate from input drift Power Supply for Analog Output Loop Or Other Uses Terminals I R 24 VDC 10 May be used to power the 4 20 mA outpu...

Страница 8: ...sted USA Canada UL 508 Industrial Control Equipment United States C22 2 No 142 Canadian National Standard UL File Number E160849 Front Panel UL Type 4X NEMA 4X IP65 Low Voltage Directive EN 61010 1 20...

Страница 9: ...by removing the single securing screw Wires should be run through the conduit entry holes located on the bottom of the meter There are a total of four pre drilled conduit entry holes located at the bo...

Страница 10: ...right on the wall 2 Using a drill bit slightly smaller than the girth of the mounting screws pre drill holes at the mounting locations previously marked 3 Insert mounting screws into the four mounting...

Страница 11: ...instructions 1 Secure the mounting plates to the top and bottom for vertical pipes or left and right for horizontal pipes of the reverse side of the meter enclosure using the provided fasteners Do no...

Страница 12: ...ation Warning Do not connect any equipment other than Precision Digital s expansion modules cables or meters to the RJ45 M LINK connector Otherwise damage will occur to the equipment and the meter Do...

Страница 13: ...menu The selected thermocouple input must correspond to the thermocouple sensor and wire type used Figure 8 Thermocouple Input Connections Figure 9 Three Wire RTD Input Connections The meter accepts t...

Страница 14: ...ard RS485 terminal block or USB connector shown in Figure 6 If RS232 is required an RS485 to RS232 adapter PDA7485 may be used See Ordering Information on page 5 for additional information Relay Conne...

Страница 15: ...F for each amp through closed contacts Notes 1 Use capacitors rated for 250 VAC 2 RC networks may affect load release time of solenoid loads Check to confirm proper operation 3 Install the RC network...

Страница 16: ...network Figure 17 shows the connection of several meters to a PC using a PDA7485 RS 232 to RS 422 485 converter in an RS 485 network When using more than one meter in a multi drop mode each meter must...

Страница 17: ...on Connections Figure 18 details the wiring connections from the RS 485 connector to an RS 422 485 serial converter such as the PDA7485 or PDA8485 for a four wire network Three Wire Connection In orde...

Страница 18: ...nnector block and the 5 VDC block Digital output connections are made by wiring from the appropriate digital output block to the grounding terminal block Figure 20 Digital Input and Output Connections...

Страница 19: ...n Interlock Relay Feature As the name implies the interlock relay feature reassigns one or more alarm control relays for use as interlock relay s Interlock contact s are wired to digital input s and t...

Страница 20: ...two switches located to the right of the signal input connector used to set the input selection for thermocouple or RTD and for 100 ohm platinum or 10 ohm copper The 1000 ohm RTD input uses the same s...

Страница 21: ...ashing Relay interlock switch open Note F4 F8 are digital inputs Note LEDs for relays in manual mode flash with the M LED every 10 seconds M flashing by itself indicates Aout manual control is used Pr...

Страница 22: ...ck on the drive labeled MAINSTAL 3 Double click on the file named MAStart The program will open a few windows and install two programs on your computer Simply follow the onscreen instructions until yo...

Страница 23: ...play intensity level from 1 to 8 RELaY Relay Enter the Relay menu RLY 1 Relay 1 Relay 1 setup Act 1 Action 1 Set relay 1 action Auto Automatic Set relay for automatic reset A nman Auto manual Set rela...

Страница 24: ...A reset Reset Press Enter to access the Reset menu Rst Hi Reset high Press Enter to reset max display Rst Lo Reset low Press Enter to reset min display Rst HL Reset high low Press Enter to reset max m...

Страница 25: ...r pressing Enter F3 The display moves to the next menu every time a setting is accepted by pressing Enter F3 Setting Numeric Values The numeric values are set using the Right and Up arrow buttons Pres...

Страница 26: ...standards There is no need to calibrate the meter simply select the input type F or C and decimal point The Setup menu is used to select 1 Input type the meter will accept 2 Degrees F or C 3 Select th...

Страница 27: ...s available only with no decimal point selected Pressing the Up arrow scrolls the decimal point and temperature format selections Setting the Display Parameter Intensity dsplay The main display line 1...

Страница 28: ...the following 7 segment character set Display Character Display Character Display Character Display Character 0 0 C C k K v V 1 1 c c l L u w w 2 2 d d m m x X 3 3 e E n n y Y 4 4 f F O O z Z 5 5 g G...

Страница 29: ...ic manual reset at any time non latching c Latching manual reset only d Latching with Clear manual reset only after alarm condition has cleared e Pump alternation control automatic reset only f Sampli...

Страница 30: ...e relay is activated for a user specified time 7 Off relay state controlled by Interlock feature The following graphic shows relay 1 action setup relay 2 4 are set up in a similar fashion Programming...

Страница 31: ...k The loop break feature is associated with the 4 20 mA input Each relay may be programmed to go to one of the following conditions when the meter detects the loss of the input signal i e 0 005 mA 1 T...

Страница 32: ...elay coil is energized in non alarm condition In case of power failure relay will go to alarm state Low Alarm with Fail Safe Operation Set Reset Note Relay coil is energized in non alarm condition In...

Страница 33: ...2 Turn Off Go to non alarm condition 3 Ignore Processed as a low signal condition Time Delay Operation The following graphs show the operation of the time delay function When the signal crosses the s...

Страница 34: ...el LEDs The LEDs on the front panel provide status indication for the following The meter is supplied with four alarm points that include front panel LEDs to indicate alarm conditions This standard fe...

Страница 35: ...In this application the meter is set up for manual reset at any time Acknowledging the alarm even if the alarm condition is still present resets the relay and turns off the LED Latching Relay Lt Clr I...

Страница 36: ...e relays for the interlock feature 1 Access the Setup Relay Action menu and set the action to off 2 In the Advanced features User menu program any of the digital inputs to Force On any of the internal...

Страница 37: ...Reset Menu reset The Reset menu is used to reset the maximum or minimum reading peak or valley reached by the process both may be reset at the same time by selecting reset high low rst HL The tare va...

Страница 38: ...settings Pass 1 Allows use of function keys and digital inputs Pass 2 Allows use of function keys digital inputs and editing set reset points Pass 3 Restricts all programming function keys and digita...

Страница 39: ...he Password menu and enter the correct password twice as shown below The meter is now unprotected until a new password is entered If the correct six digit password is entered the meter displays the me...

Страница 40: ...Enter temperature calibration menu T lo T Low Apply the low temperature input e g 32 F T Hi T High Apply the high temperature input e g 1000 F rtdtot RTD Total Set the number of RTDs connected in para...

Страница 41: ...mA resolution user User I O Assign function keys and digital I O F1 F1 function key Assign F1 function key F2 F2 function key Assign F2 function key F3 F3 function key Assign F3 function key F4 F4 fu...

Страница 42: ...t 1 Low Input 2 High Check Middle Type J 32 F 1184 F 600 F Type K 32 F 1895 F 960 F Type T 32 F 698 F 360 F Type E 32 F 1652 F 800 F Type R 32 F 3110 F 1500 F Type S 32 F 3110 F 1500 F Type B 32 F 311...

Страница 43: ...arest value according the rounding selected This setting affects the last two digits regardless of decimal point position Valid rounding values are 1 2 5 and 10 Modbus RTU Serial Communications serial...

Страница 44: ...Max Maximum analog output value allowed regardless of input 6 Min Minimum analog output value allowed regardless of input 7 Calibrate Calibrate the internal 4 20 mA source reference used to scale the...

Страница 45: ...ed to enable relays Rly E is pressed Rly E Enable all relays to function as they have been programmed O Hold Hold current relay states as they are until a button assigned to enable relays Rly E is pre...

Страница 46: ...bration procedure The T CAL procedure should be used instead of the ICAL procedure Thermocouple Input Internal Calibration ICAL 1 Set the Type selector switch in the TC position and using copper wire...

Страница 47: ...r displays the message 10 Hi Apply 18 032 ohm and press Enter The display flashes for a moment while the meter is accepting the high input signal for the 10 ohm RTD After the display stops flashing pr...

Страница 48: ...min readings or other parameter function assigned through the User menu Press to display max min readings or other parameter function assigned through the User menu Press to acknowledge relays or oth...

Страница 49: ...Reset menu The max min displays are reset to actual values 3 Press Menu to exit max min display reading To display max min readings continuously Assign either display to Max d Hi Min d Lo or toggle b...

Страница 50: ...the settings Reset Meter to Factory Defaults When the parameters have been changed in a way that is difficult to determine what s happening it might be better to start the setup process from the facto...

Страница 51: ...0 sec On delay relay 3 On 3 0 0 sec Off delay relay 3 Off 3 0 0 sec On delay relay 4 On 4 0 0 sec Off delay relay 4 Off 4 0 0 sec Input break relay 1 ignore Ignore Input break relay 2 ignore Ignore In...

Страница 52: ...Display does not respond to input changes reading a fixed number Check display assignment it might be displaying max min or set point Display alternates between Hi and a number Lo and a number Press M...

Отзывы: