ProtEX-MAX PD8-6060 Explosion-Proof Dual-Input Meter Instruction Manual
4
) ------------------------------- 52
Programmable Function Keys User Menu (
) ---------------------------------------- 55
) ------------------------------- 55
Meter Operation ----------------------------------------- 57
Front Panel Buttons Operation ------------------------- 57
Buttons ---------------------------------------- 57
F4 Operation -------------------------------------------------- 58
Maximum/Minimum Readings --------------------------- 58
Troubleshooting ----------------------------------------- 59
) ---------------------------------- 59
Determining Software Version ------------------------- 59
Reset Meter to Factory Defaults ------------------------ 59
Factory Defaults & User Settings ---------------------- 60
Troubleshooting Tips -------------------------------------- 62
Service ------------------------------------------------------ 63
Mounting Dimensions --------------------------------- 63
EU Declaration of Conformity ----------------------- 65
Table of Figures
Figure 1. Transmitter Supply Voltage Selection ....... 12
Figure 2: Integrated ProVu Required Connections .. 13
Figure 3. Connector Labeling for Fully Loaded
PD6060 ................................................................. 14
Figure 4. Power Connections ..................................... 14
Figure 5. Transmitters Powered by Internal Supply . 15
Figure 6. Transmitter Powered by Ext. Supply or Self-
Powered ............................................................... 15
Figure 7. Voltage Input Connections ......................... 15
Figure 8: ProtEX-MAX Connections to a Serial
Converter ............................................................. 16
Figure 9. Three-Wire RS485 Connection ................... 16
Figure 10: RS-485 Wiring ............................................ 17
Figure 11: RS-485 Two-Wire Multi-Drop Wiring ........ 18
Figure 12. Relay Connections ..................................... 19
Figure 13. AC and DC Loads Protection .................... 19
Figure 14. Low Voltage DC Loads Protection ........... 19
Figure 15. F4 Digital Input Connections .................... 20
Figure 16. 4-20 mA Output Connections .................... 20
Figure 17. Interlock Connections ............................... 20
Figure 18: Digital I/O Connections ............................. 21
Figure 19. Acknowledge Relays w/Function Key or
Digital Input .......................................................... 41
Figure 20: General Four-Wire Network Connection .. 49
Figure 21: General Two-Wire Network Connection... 49
Figure 22: Enclosure Dimensions – Front View ........ 63
Figure 23: Enclosure Dimensions – Side Cross
Section View ......................................................... 63
Introduction
The ProtEX-MAX PD8-6060 offers all the functionality of the ProVu PD6060 as a fully FM, CSA,
ATEX, and IECEx approved explosion-proof product. It accepts two inputs of either a process
current (4-20 mA) or process voltage (0-5V, 1-5V, etc.) signal. It displays these signals on a
dual-line, 6-digit SunBright® sunlight readable display. Its superluminous LED digits make it
easily readable in smoke, dust, fog, and, with the optional SunBright® display, even direct
sunlight. The meter can be customized such that these two inputs are displayed in a variety of
ways, including both at the same time with tags or the result of math functions performed on one
or both of the inputs.
The PD8-6060 includes a 24 VDC power supply to drive the transmitter and can be equipped
with up to four internal relays and a 4-20 mA analog output. It can be programmed and operated
without opening the housing by using the built-in SafeTouch® through-glass buttons or the
RS485 serial communication port with free Modbus® protocol.
Various math functions may be applied to the inputs including addition, difference, absolute
difference, average, weighted average, multiplication, division, minimum, maximum, draw, ratio,
and concentration. This is in addition to the signal input conditioning functions (linear, square
root, programmable exponent, or round horizontal tank calculations). The displays, relays, and
the analog output may be assigned to input channels A or B, or math result channel C.
The basic model includes an isolated 24 VDC transmitter power supply that can be used to
power the input transmitters or other devices. An additional isolated 24 VDC power supply is
included with the 4-20 mA output option. A digital input is standard. A fully loaded PD6060 meter
has the following: four SPDT relays, 4-20 mA output, and two 24 VDC power supplies.