ProtEX-MAX PD8-6060 Explosion-Proof Dual-Input Meter Instruction Manual
23
Front Buttons and Status LED Indicators
Button Symbol
Description
LED
Status
Menu
1-8
Alarm 1-8 indicator
Right arrow/F1
1-8
M
Flashing: Relay in manual
control mode
Up arrow/F2
A
B
C
Channel displayed
Flashing: Tare
Enter/F3
1-4
Flashing: Relay interlock
switch open
Notes:
F4-8 are digital inputs.
Note:
LEDs for relays in manual mode
flash with the “M” LED every 10
seconds.
•
Press the Menu button to enter or exit the Programming Mode at any time.
•
Press the Right arrow button to move to the next digit during digit or decimal point programming.
•
Press or hold the Up arrow button to scroll through the menus, decimal point, or to increment the
value of a digit.
•
Press the Enter button to access a menu or to accept a setting.
•
Press and hold the Menu button for three seconds to access the advanced features of the meter.