8 Create a new Method
■
19
En
gl
is
h
Is the text data entry completed
• Press
{
E
}
to finish and save your input
• Press
{
!
}
to select „Number“
• Press
{
E
}
to confirm your selection
• Enter the group number, e.g. „1“
• Press
{
E
}
to finish and save your input
• Press
«ESC»
• Press
{
E
}
• Keep pressing
{
!
}
until the menu item „NEW“ Method is selected. (If no method has been defined only
„NEW“ is available.)
• Press
{
E
}
to confirm your selection
• Define your method going through all parameters:
• Turn the page with
{
%
}/{
}
respectivly
Properties: Show
Shows all settings of the method
Name:
Enter the name of the method
Number: ()
Enter the number of the method
Intervall 1-3:
A method consists of 1 to 3 intervals with individual temperature, heating mode, unit...
The activated intevals are marked with an asterix. (See below)
Resolution: standard/
heigh
Standard (d=1 mg)
Heigh (d=0.1 mg)
Standby temperature:
Standby temperature (50 - 100 °C) which is holed inbetween two measurements
NOTE
Executing text data entries, numbers put in with the soft key functions
{12345}
and
{67890}
act as cara-
cters, not as numeric values.
Method group - DAIRY - New method
1/2
Properties
#
Show
Name
Number
()
* Interval 1
Define
Interval 2
Define
Interval 3
Define
ESC
%
"
!
E
Method group - DAIRY - New method
2/2
Resolution
Standard
Standby temperature
Define
Dryer Control
#
Define
CheckWeigher
Define
Ash Residue
Define
ESC
%
"
!
E