Troubleshooting
46
Symptom
Possible cause:
Remedy
When the tool is
released no fasteners
are driven in (empty
shot)
The pusher spring is
defective.
Notify customer service
(see page 61 ).
The magazine is
fouled.
Clean the magazine.
The wrong fasteners
are loaded in the
magazine.
Empty the magazine
(see page 36).
Only fill the magazine
with PREBENA fasteners
that are suitable for the
device
(see page 36).
Insufficient operating
pressure.
Increase operating
pressure (see page 29,
only for
PKT-2-ES40-S,
PKT-2-ES40-SY,
PKT-2-CLIP45-SY and
PKT-2-N65-S)
Change the compressed
air cartridge (see page
29).
The piston with the
driver does not return
to start position after
the driving process.
Notify customer service
(see page 61).
The release process
does not execute
completely.
Notify customer service
(see page 61).
The driver is bent
Notify customer service
(see page 61).
Fasteners jam.
Remove the jammed or
bent fastener (see page
47)