Praxair
®
StarWatch Connect Website
P-15-748
User Guide
Issued: 11 Jul 2016, Revised: 12 Oct 2016
Page 23 of 35
Definition of Fields that are Used to Create Each Alert
Device Group
: This displays the name(s) of group(s) that the single alert will
be applied to.
Tags (optional)
: As mentioned above, tags can be applied to devices (see
section 1.3.1) and sensors (see section 1.3.3). Adding tags to a group alert
will restrict the alert to only those devices or sensors within the group that
possesses the selected tag.
Alert Name
: Add a name for the alert. This name will be included in
notifications, so it is recommended to use a name that will help you identify the
application or location impacted by the alert.
Notification Frequency
: With Alert Frequency set to “Only send once,” an
alert is only sent the first time the reading crosses the specified Alert
Threshold. For the other Alert Frequency settings, an alert is sent at the
specified interval as long as the reading remains beyond the Threshold Value.
As a later option, an alert can also be sent if/when the reading returns to
normal (see All Clear).
Acknowledgement
:
•
If the box is unchecked, alerts will be sent at a specified interval until the
reading returns to normal.
•
If the box is checked, alerts will stop being sent when the reading
returns to normal or when a user logs into the
StarWatch
Connect
Website and acknowledges the alert.
Alert Type and Alert Threshold
: The following alert types are available:
•
Level
: Available for
StarWatch
Connect transmitters only. An alert
notification will be sent when the level sensor reading crosses the Alert
Threshold value.
•
Low Battery
: Available for
StarWatch
Connect transmitters only. An
alert notification will be sent when the device has less than 20 percent
battery remaining.
•
Missed Report
: Available for
StarWatch
Connect gateways and
transmitters. An alert notification will be sent if the
StarWatch
Connect
Website fails to receive readings from a device for the number of
intervals specified in the Alert Threshold. The minimum number of
intervals is 4. For example, if a device’s Monitoring Interval is set to 5
minutes and the Alert Threshold is set to 4 intervals, the
StarWatch
Connect Website will send an alert notification after 20 minutes of the
device not reporting.
Содержание StarWatch
Страница 1: ...P 15 754 Issued 12 Oct 2016 User Guide Praxair StarWatch Connect Website ...
Страница 4: ...User Guide P 15 754 Page iv of ix Issued 11 Jul 2016 Revised 12 Oct 2016 ...
Страница 42: ......
Страница 44: ...Appendix A User Guide P 15 754 Issued 11 Jul 2016 Revised 12 Oct 2016 ...
Страница 46: ......