Operating problems, causes and remedies
Error messages (power source)
56
Item No.: 099-004838-PRA01
8
Operating problems, causes and remedies
8.1
Error messages (power source)
All machines are subject to rigorous production and final checks. If, despite this, anything fails to work at
any time, please check machine using the chart below. If none of the fault rectification procedures
described leads to the correct functioning of the machine, please inform your authorised dealer.
A welding machine error is indicated by an error code being displayed (see table) on the display
on the machine control.
In the event of a machine error, the power unit is shut down.
• If multiple errors occur, these are displayed in succession.
• Document machine errors and inform service staff as necessary.
Category
Error
a) b)
Possible cause
Remedy
Err 1
- x
Mains overvoltage
Err 2
- x
Mains undervoltage
Check the mains voltages and compare with
the welding machine connection voltages
(see Technical data, chapter 1)
Err 3
x -
Welding machine - excess
temperature
Allow the machine to cool down (main
switch to "1")
Err 4
- x
Coolant level low
Top up the coolant
Leak in the coolant circuit > rectify the leak
and top up the coolant
Coolant pump is not working > check excess
current trigger on air cooling unit
Err 5
- x
Error in WF case, tachometer
error
Check the wire feed unit
Tachometer generator not issuing a signal,
M3.00 defective > inform Service
Err 7
- x
Secondary excess voltage
Inverter error > inform Service
Err 8
- x
Earth fault between welding
wire and earth line
(PHOENIX 330 only)
Separate the connection between the
welding wire and casing or an earthed object
Err 9
x -
Fast shut-down triggered by
BUSINT X10 or RINT X11
Rectify error on robot
Err 10
- x
Arc interruption
Triggered by BUSINT X10 or
RINT X11
Check wire feed
Err 11
- x
Ignition error after 5 seconds
Triggered by BUSINT X10 or
RINT X11
Check wire feed
Category legend for error reset
a) The error message will disappear once the error has been rectified.
b) Errors can only be reset by switching the machine off and back on again.
Содержание PHOENIX 401 BASIC PULS forceArc
Страница 7: ...Safety instructions PHOENIX 401 BASIC PULS forceArc Item No 099 004838 PRA01 7 2 Safety instructions ...
Страница 8: ...Safety instructions PHOENIX 401 BASIC PULS forceArc 8 Item No 099 004838 PRA01 ...
Страница 9: ...Safety instructions PHOENIX 401 BASIC PULS forceArc Item No 099 004838 PRA01 9 ...
Страница 18: ...Machine description PHOENIX BASIC DRIVE 4L 18 Item No 099 004838 PRA01 4 2 2 Rear view Figure 4 4 ...