4. CONNECTION AND SET UP OF THE CONTROL UNIT
a)
Before installing the UNIK2E230 control unit, read the “General safety warnings and
notes” (page 15).
b)
Mount a differential thermo-magnetic circuit breaker 6A (IC=30mA) on the mains supply
as specified in the current reference standards (IC = differential current).
c)
*
Fix the box using the special fixing holes.
d)
*
Place the supplied cable-ways and insert the cables keeping the power and supply
cables separate from each other.
e)
Connect the motors to the terminal blocks “MOT1” e “MOT2”; if only one motor is used
connect it to the terminal blocks “MOT1”.
f)
Connect the external accessories making sure that the total of the average absorption
of all the connected accessories is less than the maximum current available (see info
page 13).
g)
ATTENTION: Connect the limit switches if present, otherwise do not bridge inputs
FC1, FC2, FO1, and FO2 in the terminal board.
h)
ATTENTION: To avoid noisy or irregular operating when the control panel is used
with hydraulic operators, the following is recommended:
•
set the Force to 100% (“FOR” trimmer completely clockwise).
•
do not use the slow-down (carry out the professional learning procedure).
•
do not use the obstacle detection (trimmer OBS to MAX),
i)
During the learning with no electric limit switches present and with the obstacle
detection disabled (e.g. with hydraulic operators), or else with no mechanical
STOP (strike plate) present, to define the manoeuvre times:
•
Press pushbutton 1 of the remote control or pushbutton P1/SET to stop the gate in the
desired position.
•
Press pushbutton 2 of the remote control or pushbutton P2/SET to stop the gate in the
desired position.
j)
Check the correct connection and operation of all the accessories connected to the
terminal board.
NOTE:
*
When the control panel is mounted directly onto the operator with the special control
panel-holder, these two points are not relevant.
INITIAL FACTORY SETTINGS
If there is no programming, the control unit will operate as follows:
•
Step by step mode with automatic closing disabled
•
No slow-down
•
Closing safety present
•
No opening safety
•
Obstacle detection trigger time (OBS) 1 second
•
3 second opening and closing time of the motors
•
Pushbutton 1 of transmitters enabled
•
Safety test disabled
•
Kick-back disabled