a) Power loss
Cause:
The power supply has been interrupted
Action:
When the Aquastar is at an unsafe position it approaches filter if the main
supply is back.
Signal:
1s
Reset:
Connect power.
Possible reasons:
Power loss. Cable break
b) Current error
Cause:
The permitted motor current has been exceeded
Action:
The motor stops. After two seconds the Aquastar retries to reach position
Signal:
3s
Reset:
No need to reset. If current is below current-limit in the next attempt,
normal operation goes on
Possible reasons:
Aquastar is not enough fixed to the valve
c) Current error state
Cause:
The permitted motor current has been exceeded three times in this
position cycle
Action:
Aquastar is set to errorstate. No possible actions until Aquastar is reset
Signal:
4s
Reset:
Press “ON” and “OFF” Button simultaneously for at least 5s
Possible reasons:
Aquastar I not enough fixed to the valve. Motor is broken. Valve is broken.
Pump has not been turned off. Water column of 3 meter exceeded.
d) One Hall error state
Cause:
Chosen position has not been reached within 3 minutes or 3 rounds.
Action:
Aquastar is set to errorstate. No possible actions until Aquastar is reset
Signal:
5s
Reset:
Press “ON” and “OFF” Button simultaneously for at least 5s
Possible reasons:
Defective electronics
e) Hall error state
Cause:
Motor has been turned on but no position change for 30 seconds
Action:
Aquastar is set to errorstate. No possible actions until Aquastar is reset
Signal:
6s
Reset:
Press “ON” and “OFF” Button simultaneously for at least 5s
Possible reasons:
Defective electronics. Insufficient power supply. Motor is broken. End pos.
switch is not connected. Motor is not connected.