12
www.praher-plastics.com
Backwash time Switch SW1
The backwash time is set with the switch SW1 on the control board.
Four backwash times are available.
Rinsing time Switch SW2
The rinsing time is set with the switch SW2 on the control board.
Four rinsing times are available.
Switchpoints backwash time Switch SW3
The switch points for backwash time are set with switch SW3 on the control board.
Four switch points for backwashing are available.
ATTENTION! Prior to setting/adjusting the switchpoints ‘backwashing’ the valve needs to
be on position ‘FILTER’ and the Aquastar has to be turned off (see page 11)
Time of activation of backwash cycle
Example: Backwash every Monday 09:15
set switch SW3 to switch point 7 days and
turn on the Aquastar at 09:15 (press „ON“ button on the keyboard)
In order to alter the time of activation, just press the “TEST BUTTON” on the keyboard at the
wanted activation time.
Example: Change activation from Monday 09:15 to Friday 08:00
„TEST“ button at the keyboard on Friday 08:00