10
www.praher-plastics.com
Sequence of cycles
Start position FILTER
–
device ON
Start of backwash cycle by pressing the test key on the keyboard
Control lamp ‘test key’ for backwash cycle is illuminated
Output ‘pump’ clamp [13]-[14] switches off (no alley)
Output ball valve switches from clamp [G]-[4] to [G]-[3]
Pump set Pump delay elapses
Valve goes to backwash position
Pump time delay of approx. 1 sec. elapses
Output ‘pump’ clamp [13]-[14] closes
Preset backwash time is counting down (switch S1)S
Output ‘pump’ clamp [13]-[14] switches off (no alley)
Pump set Pump delay elapses
Valve goes to rinsing position
Pump time delay of approx. 1 sec. elapses
Output ‘pump’ clamp [13]-[14] closes
Pre-set rinsing time is counting down (switch S2)
Output ‘pump’ clamp [13]-[14] switches off (no alley)
Pump set Pump delay elapses
Valve goes to filter position
Output ball valves switches from clamp [G]-[4] to [G]-[3]
Pump delay time of approx. 1sec is counting down
Output ‘pump’ clamp [13]-[14] closes
Flushing and changeover times
Time delay pump ON
5 sec
CHANGEOVER
Filter
–
Backwash
approx. 30 sec
Backwash
45 sec / 360 sec
CHANGEOVER
Backwash time - Rinsing
approx. 22 sec
Rinsing
20 sec / 90 sec
CHANGEOVER
Rinsing - Filter
approx. 18 sec.
Cycle time
approx. 2 min 34 sec / approx. 9 min