9 Assembly
Device installation
– installation of the valve
Install the valve in the conduit according to the labeling and the sketch below. Use adapter
unions. Threaded connections should be sealed only with Teflon strip. Although the device is
functional in any position, it must not be installed with the actuator facing down.
If the difference in level between system and tank exceeds 3 meters, stop valves or non-
return valves should be installed to prevent severe damage to the actuator and the valve
due to excessive pressure and flow.
As filter medium can be washed out during backwashing and rinsing, we recommend fitting
the drain with a throttle. Otherwise a stuck valve disk can adversely affect the flawless
functioning of the Aquastar. Polluted or grainy filtering media require the use of adequate pre
filters.
Important! During a cycle the filter pump motor must be shut off!
The Praher Aquastar Comfort is approved for 6-way valves by Praher. Malfunctions
can occur with any other valve type as we are unable to guarantee that these valves
match the dimensions of the Praher 6-way valves.
9.1 Function- and installation diagram
6 way valve type:
11/2“, 2“ and 3“
Connections:
thread or solvent socket (all connections open)
Max. operating pressure:
ABS 11/2“, 2“, 3“ 3,5 bar
GFK 11/2“, 2“
6 bar
GFK 3“
5 bar
Filtern der Flüssigkeit
(z.B. Wasser)
Becken
Pumpe
Ventil
(zum Filter)
Filter
Ventil (vom Filter)
Becken
Filtering the medium (i.e. water)
Pool → Pump → Valve (towards
filter) → Filter → Valve (away
from Filter)
→ Pool
=Klarspülen
Filtermedium reinigen(z.B.
Sand) nach dem Rück-
spülen
Becken
Pumpe
Ventil
(zum Filter)
Filter
Ventil (vom Filter)
Kanal
Cleaning filter medium
(i.e. sand) after backwash cycle
Pool → Pump
→ Valve (towards filter) → Filter
→
Valve (away from filter)
→ sewer
Filtermedium reinigen (z.B.
Sand) im Gegenstrom
(umgekehrte Durchfluss-
richtung im Filter)
Becken
Pumpe
Ventil
(vom Filter)
Filter
Ventil (zum Filter)
Kanal
Cleaning filter medium
(i.e. sand) in counter flow
(reversed flow direction in filter)
Pool → Pump
→ Valve (away from filter) → Filter
→ Valve (towards filter) → sewer
Entleeren vom Becken
mit der Pumpe
Becken
Pumpe
Ventil
Kanal
Draining of the pool
with the pump
Pool
→ Pump
→ Valve → Sewer
Umpumpen der Flüssigkeit
ohne Filter (Filter ist
überbrückt)
Becken
Pumpe
Ventil
Becken
Circulating the medium
without Filter (Filter is bypassed)
Pool
→ Pump
→ Valve → Pool
Pump
→ away from pump
Top
→ towards filter
Bottom
→ away from filter
Return
→ towards pool
Waste
→ towards sewer
Pump
von Pumpe
Top
zum Filter
Bottom
vom Filter
Return
zum Becken
Waste
zum Kanal
Содержание Aquastar Comfort 1001
Страница 1: ...Zertifiziert nach certified acc to EN ISO 9001 2008...
Страница 4: ...www praherplastics com 4...
Страница 18: ...www praherplastics com 18 16 8 Datum und Uhrzeit einstellen...
Страница 21: ...21 www praherplastics com 19 Anschlussplan f r Pumpe...
Страница 22: ...www praherplastics com 22 20 Platinen Platine f r alle Comfort Typen Platine f r 100 240 V AC 24 V AC DC...
Страница 29: ...29 www praherplastics com Notizen Notes...
Страница 32: ...www praherplastics com 4...
Страница 46: ...www praherplastics com 18 16 8 Setting of date and time...
Страница 49: ...21 www praherplastics com 19 Connection diagram for pump...
Страница 50: ...www praherplastics com 22 20 Control boards for all Comfort types Control board for 100 240 V AC 24 V AC DC...
Страница 57: ...29 www praherplastics com Notes...
Страница 58: ...www praherplastics com 30 Notes...
Страница 59: ...31 www praherplastics com Notes...
Страница 60: ...Praher Plastics Austria GmbH BA DEEN 15 02 182 C 90377A...