background image

 

DMX CONTROL CONNECTION:

 

 

 

 
Connection between controller and projector and between one projector and another must be made with a twin-screened cable, with 
each wire having at least a 0.5mm in diameter. Connection to and from the projector is via cannon 3 pin (which are included with the 
projector) or 3 pin XLR plugs and sockets. The XLR's are connected as shown in the figure above.   
 
Note: care should be taken to ensure that none of the pins touch the metallic body of the plug or each other. XLR plugs and sockets 
mustn’t be connected in any way other than mentioned in the above figure. The projector accepts digital control signals in protocol 
DMX512 (1990).   
 
Connect the controller’s DMX output to the first fixture’s DMX input, and connect the first fixture’s DMX output to the second 
fixture’s DMX input and connect the rest fixtures in the same way. Eventually connect the last fixture’s DMX output to a DMX 
terminator as shown in the figure below.   
 
 

 

 

DMX TERMINATOR   

In the Controller mode, at the last fixture in the chain, the DMX output has to be connected with a DMX terminator. This prevents 
electrical noise from disturbing and corrupting the DMX control signals. 
The DMX terminator is simply an XLR connector with a 120

 (ohm) resistor connected across pins 2 and 3, which is then plugged 

into the output socket on the last projector in the chain. The connections are illustrated below. 

 

 
 
 

 
 
 

DMX IN

DMX OUT

DMX IN

DMX OUT

DMX IN

DMX OUT

POWER

POWER

POWER

2

1

3

120

DMX TERMINATOR

CONNECTION

Connect a 120    (OHM) resistor

across pins 2 and 3 in an XLR plug
and insert into the DMX out socket 

on the last unit in the chain. 

PIN 3

PIN 2

Содержание ARC LED 372

Страница 1: ...contains important information about the safe installation and use of a projector Please read and follow these instructions carefully and keep the manual in a safe place for future reference PR LIGHTI...

Страница 2: ...underwater dusty area Please note that as part of our ongoing commitment to continuous product development specifications are subject to change without notice Whilst every care is taken in the prepar...

Страница 3: ...device to any type ofdimmer pack After lamp switched on the minimum distance between the projector and illuminated surface is 1 5m If projector s lamp lens and screen s protective cover have obvious...

Страница 4: ...ions and its environment Use soft cloth and normal detergent for glass for cleaning work It s advised external optical system be cleaned every 20days Keep lens clean and do not touch optical parts wit...

Страница 5: ...is as follows Place barn door support 14 via threads in the head 15 then use 4 screws 12 to mount the barn door on the barn door support to complete its completion To achieve light closing effect desi...

Страница 6: ...to mount the projector to is secure and strong enough to support the weight of a unit WARNING The projector MUSTbe lifted or carried by the HANDLES instead ofclamps For safety the safety cord should a...

Страница 7: ...re s DMX input and connect the first fixture s DMX output to the second fixture s DMX input and connect the rest fixtures in the same way Eventually connect the last fixture s DMX output to a DMX term...

Страница 8: ...nit has 2 DMX modes There are standard mode and extended mode For example standard mode has 6 channels so set the No 1 projector s address 001 No 2 projector s address 007 No 3 projector s address 013...

Страница 9: ...DMX terminator Set 1st projector as the master and others are Slaves Start Addresses ofall Slaves are 001 Operation mode of the Master can be set any mode for a Master and Slaves operation mode can b...

Страница 10: ...ANSI E1 20 SoftwareVer X X X DisplayofSoftwareVersion Test Mode Red Green Blue White RGB RG RB GB RWB RGBW Operation Mode DMX Mode Yes User Memory Yes Preset Memory PR01 PR16 User Progra Edit ET01 ET...

Страница 11: ...herwise on If t2 t1 the unit is on 2 if the unit is set as controlled by environment brightness the brightness that turns the unit on is set as b1 and the one that turns it off is b2 the current envir...

Страница 12: ...y5 080 095 Preset memory6 096 111 Preset memory7 112 127 Preset memory8 128 143 Preset memory9 144 159 Preset memory10 160 175 Preset memory11 176 191 Preset memory12 192 207 Preset memory13 208 223 P...

Страница 13: ...ed LED indication On DMX signal OK Off No DMX signal Blue LED indication On Linked with a transmitter Off Not linked with anytransmitter Flash Being linked with a transmitter or losing link with it or...

Страница 14: ...less DMX Signal Control Master Slave Synchronized control Mode 3 Operation Modes DMX Mode Preset Memory user Memory Test Mode OTHER FUNCTIONS LED lamp board temperature and fixture time available in t...

Страница 15: ...15 LIGHTOUTPUT 45 lens DISTANCE m 2m 2m 0m 1m 1m 0 5 10 15 20 25 30 DIAMETER m 0 43 0 85 1 28 1 70 2 13 2 55 0 13260 7718 3430 1929 1235 858 0 lux...

Страница 16: ...16 11 CIRCUITDIAGRAMAND PCB CONNECTIONS CIRCUITDIAGRAM...

Страница 17: ...17 PCB CONNECTIONS...

Страница 18: ...8805 LED LAMPBOARD 1 PWM singnal input 2 LED driver output2 3 LEDdriver output1 4 Power input 1 LED driver input1 1 2 3 4 5 6 7 PWM 7 6 5 4 1 2 3 1 2 3 4 5 6 7 Optical sensor Thermal switch Power sup...

Страница 19: ...ch 192010213 1 5 PR 8805 LEDlampboard 230060843 1 6 PR 8805mainboard 230060844 1 PR LIGHTING LTD 1582 XingyeAvenue Nancun Panyu Guangzhou 511442 China TEL 86 20 3995 2888 PR lighting will try its best...

Отзывы: