background image

 

5. INSTALLATION( For reference only)   

 

RIGGING   

 

 

 

        Before moving the unit, lock the adjusting knob. 

Take 2 clamps and the safety cord out from the package and mount 2 clamps on the underside of fixture with 2 retainers attached 
to each clamp. Hang the fixture on the structure and fasten the screws attached to each clamp. (See the 

WARNING

 on the 

underside of the base as shown above) 

To pass the SAFETY CORD through the HOLES for safety!

 Always ensure that the 

projector is firmly anchored to avoid vibration and slipping whilst functioning. Always ensure that the structure that you are going 
to mount the projector to is secure and strong enough to support the weight of a unit. 
 

 

WARNING:   

The projector MUST be lifted or carried by the HANDLES instead of clamps.

 

.For safety the safety cord should afford 10 times the Projector’s weight. 

 
 

   

POWER CONNECTION

 

 

   

Connect the power cord as follows: 

      L (live) =brown 
      E (earth) =yellow/green 
      N (neutral) =blue 

   

Note: Before power connection, please ensure the power supplied must match what the nameplate says.   
 

 

 

The  earth  wire(yellow/green)  must  be  connected  to  the  ground.  And  electrical  connection  must  be  in 

accordance with the standards concerned. 

If any questions about the electrical installation, do not continue but consult a qualified electrician.

 

 
 

 
 
 

Clamp

Clamp

Safety Cord

Handle

Adjusting Knob

Warning: please run

the safety cord through

the arm for safety.

Содержание ARC LED 372

Страница 1: ...contains important information about the safe installation and use of a projector Please read and follow these instructions carefully and keep the manual in a safe place for future reference PR LIGHTI...

Страница 2: ...underwater dusty area Please note that as part of our ongoing commitment to continuous product development specifications are subject to change without notice Whilst every care is taken in the prepar...

Страница 3: ...device to any type ofdimmer pack After lamp switched on the minimum distance between the projector and illuminated surface is 1 5m If projector s lamp lens and screen s protective cover have obvious...

Страница 4: ...ions and its environment Use soft cloth and normal detergent for glass for cleaning work It s advised external optical system be cleaned every 20days Keep lens clean and do not touch optical parts wit...

Страница 5: ...is as follows Place barn door support 14 via threads in the head 15 then use 4 screws 12 to mount the barn door on the barn door support to complete its completion To achieve light closing effect desi...

Страница 6: ...to mount the projector to is secure and strong enough to support the weight of a unit WARNING The projector MUSTbe lifted or carried by the HANDLES instead ofclamps For safety the safety cord should a...

Страница 7: ...re s DMX input and connect the first fixture s DMX output to the second fixture s DMX input and connect the rest fixtures in the same way Eventually connect the last fixture s DMX output to a DMX term...

Страница 8: ...nit has 2 DMX modes There are standard mode and extended mode For example standard mode has 6 channels so set the No 1 projector s address 001 No 2 projector s address 007 No 3 projector s address 013...

Страница 9: ...DMX terminator Set 1st projector as the master and others are Slaves Start Addresses ofall Slaves are 001 Operation mode of the Master can be set any mode for a Master and Slaves operation mode can b...

Страница 10: ...ANSI E1 20 SoftwareVer X X X DisplayofSoftwareVersion Test Mode Red Green Blue White RGB RG RB GB RWB RGBW Operation Mode DMX Mode Yes User Memory Yes Preset Memory PR01 PR16 User Progra Edit ET01 ET...

Страница 11: ...herwise on If t2 t1 the unit is on 2 if the unit is set as controlled by environment brightness the brightness that turns the unit on is set as b1 and the one that turns it off is b2 the current envir...

Страница 12: ...y5 080 095 Preset memory6 096 111 Preset memory7 112 127 Preset memory8 128 143 Preset memory9 144 159 Preset memory10 160 175 Preset memory11 176 191 Preset memory12 192 207 Preset memory13 208 223 P...

Страница 13: ...ed LED indication On DMX signal OK Off No DMX signal Blue LED indication On Linked with a transmitter Off Not linked with anytransmitter Flash Being linked with a transmitter or losing link with it or...

Страница 14: ...less DMX Signal Control Master Slave Synchronized control Mode 3 Operation Modes DMX Mode Preset Memory user Memory Test Mode OTHER FUNCTIONS LED lamp board temperature and fixture time available in t...

Страница 15: ...15 LIGHTOUTPUT 45 lens DISTANCE m 2m 2m 0m 1m 1m 0 5 10 15 20 25 30 DIAMETER m 0 43 0 85 1 28 1 70 2 13 2 55 0 13260 7718 3430 1929 1235 858 0 lux...

Страница 16: ...16 11 CIRCUITDIAGRAMAND PCB CONNECTIONS CIRCUITDIAGRAM...

Страница 17: ...17 PCB CONNECTIONS...

Страница 18: ...8805 LED LAMPBOARD 1 PWM singnal input 2 LED driver output2 3 LEDdriver output1 4 Power input 1 LED driver input1 1 2 3 4 5 6 7 PWM 7 6 5 4 1 2 3 1 2 3 4 5 6 7 Optical sensor Thermal switch Power sup...

Страница 19: ...ch 192010213 1 5 PR 8805 LEDlampboard 230060843 1 6 PR 8805mainboard 230060844 1 PR LIGHTING LTD 1582 XingyeAvenue Nancun Panyu Guangzhou 511442 China TEL 86 20 3995 2888 PR lighting will try its best...