Inputs:
Sensor types:
NAMUR according to .............................. EN 60947-5-6
Mechanical switch with
series
(R
s
) and parallel (R
p
) resistance:
R
s
............................................................. Nom. 750
R
p
............................................................ Nom. 15 k
Frequency range ......................................... 0...5 kHz
Min. pulse length ......................................... > 0.1 ms
Input resistance ........................................... Nom. 1 k
Trig level, signal ........................................... < 1.2 mA, > 2.1 mA
Trig level, cable fault.................................... < 0.1 mA, > 6.5 mA
Outputs:
Relay outputs:
Status relay:
Max. voltage ............................................ 125 VAC / 110 VDC
Max. current ............................................ 0.5 A AC / 0.3 A DC
Max. power ............................................. 62.5 VA / 32 W
Relay outputs:
Max. switch frequency ............................ 20 Hz
Max. voltage ............................................ 250 VAC / 30 VDC
Max. current ............................................ 2 A AC / 2 A DC
Max.power .............................................. 500 VA / 60 W
Opto, NPN outputs:
Max. switch frequency ............................ 5 kHz
Min. pulse length ..................................... 60
s
Max. load, current / voltage. ................... 80 mA / 30 VDC
Voltage drop at 80 mA ............................ < 2.5 VDC
Marine approval:
Det Norske Veritas, Ships & Offshore ......... Pending
GOST R approval:
VNIIFTRI, Cert No. ....................................... See www.prelectronics.com
SIL certification:
exida, Cert No. ............................................ PREl 070902 P0002 C01
Observed authority requirements:
Standard:
EMC 2004/108/EC ...................................... EN 61326-1
LVD 2006/95/EC .......................................... EN 61010-1
ATEX 94/9/EC .............................................. EN 60079-0, -11, -15 , -26
and EN 61241-0, -11
IECEx ........................................................... IEC 60079-0, -11, -15 and -26
IEC 61241-0 and -11