6
5333V113-UK
Output:
Current output:
Signal range ............................................................... 4...20 mA
Min. signal range ...................................................... 16 mA
Updating time ........................................................... 135 ms
Load resistance.........................................................
≤
(V
supply
- 8) / 0.023 [
Ω
]
Load stability ............................................................. < ±0.01% of span / 100
Ω
Sensor error detection:
Programmable ........................................................... 3.5...23 mA
NAMUR NE43 Upscale ........................................... 23 mA
NAMUR NE43 Downscale ..................................... 3.5 mA
Of span = Of the presently selected range
Approvals:
EMC ................................................................................ 2014/30/EU
CCOE .............................................................................. P337392/3
RoHS ............................................................................. 2011/65/EU
EAC ................................................................................. TR-CU 020/2011
Marine approval:
DNV-GL, Ships & Offshore .................................... Standard for Certification No. 2.4
Ex / I.S.:
ATEX 2014/34/EU
5333A ...................................................................... KEMA 10ATEX0003 X
5333D...................................................................... KEMA 03ATEX1535 X
FM certificate ............................................................ FM17US0013X
CSA certificate .......................................................... 1125003
IECEx ............................................................................. DEK 13.0036 X
INMETRO ..................................................................... DEKRA 16.0014 X
CCOE .............................................................................. P337392/4
EAC Ex TR-CU 012/2011 ..................................... RU C-DK.GB08.V.00410