4
5333V113-UK
Electrical specifications
Specifications range:
-40°C to +85°C
Common specifications:
Supply voltage, DC
Standard .................................................................. 8...35 V
CSA, FM, ATEX, IECEx & INMETRO ................ 8...30 V
Internal power dissipation
Standard .................................................................. 25 mW...0.8 W
CSA, FM, ATEX, IECEx & INMETRO ................ 25 mW...0.7 W
Voltage drop .............................................................. 8 VDC
Warm-up time ............................................................ 5 min.
Communications interface ................................... Loop Link
Signal / noise ratio .................................................. Min. 60 dB
Response time (programmable) ......................... 0.33...60 s
Signal dynamics, input ........................................... 19 bit
Signal dynamics, output ....................................... 16 bit
Calibration temperature ........................................ 20...28°C
Order: 5333
Type
Version
5333
Standard
: A
CSA, FM, ATEX, IECEx & INMETRO
: D