These recommendations are a guideline for typical conveyor applications. They do not overrule bearing or greasing manufacturer’s
recommendations.
PPI recommends a high-quality, #2 Lithium Complex based mineral oil grease with a viscosity of 200 to 250. Mobilgrease XHP222 is
suggested to be used on conveyor pulley applications, including the SSP. When used with an automatic greasing system, a #1 Lithium
Complex grease is recommended, such as Mobilgrease XHP221 This is compatible with the initial grease fill. For ambient temperatures from
-40°F to 0°F (-40°C to -18°C), it is recommended that a Lithium Complex based synthetic oil grease is used, such as Mobilith SHC220.
Suggested greasing intervals during initial use are as follows:
Check the grease condition for excessive oiliness or dirt and adjust
greasing frequency accordingly. For conditions and/or temperatures
outside of this range, consult with a reputable lubricant supplier.
PPI grease fills conveyor pulley bearings 100% at the factory. This
reduces the possibility of condensation in the housing. This is the
preferred method for larger, slower speed bearings such as those
used on pulleys. Therefore, some grease may be purged out during
the first run of the pulley. This is considered normal. After 8 hours of
initial use, all bearings should be re-greased with fresh grease.
Precision Pulley & Idler cannot be held responsible for performance of individual batches of grease. Changes in lubricant specifications, performance, and
lubricant guarantees are the responsibility of the lubricant manufacturer.
Warranties shall not apply to any product that has been subject to misuse, misapplication, neglect (including but not limited to improper maintenance and
storage), accident, improper installation, modification (including but not limited to use of unauthorized parts or attachments) adjustment, repair, or lubrication.
Misuse also includes, without implied limitation, deterioration in the product or part caused by chemical action, wear caused by the presence of abrasive
materials, and the improper lubrication. Identifiable items manufactured by others but installed in or affixed to our products are not warranted by us, but bear
only those warranties, express or implied, given by the manufacturer of that item, if any.
Responsibility for system design to ensure proper use and application of Precision Pulley & Idler products within their published specifications and ratings
rest solely with the customer. This includes without implied limitation analysis of loads created by vibrations within the entire system regardless of how
induced.
SECTION 1 – GREASING RECOMMENDATIONS
OPERATION & MAINTENANCE
STATIC SHAFT PULLEY (SSP
®
)
SUGGESTED GREASING INTERVALS
Conditions
up to 120°F
(up to 50°C)
120° to 200°F
(50° to 90° C)
Clean
2 to 6 months
1 to 2 months
Moderate
Monthly
1 to 4 weeks
Dirty
Weekly
1 to 7 days
Extremely Dirty
Daily
Every Shift
Turnover Pulleys
Daily to Weekly
Every Shift