Step 2: Set the operation mode according to the 

following procedures

:

'Coded PPA' Mode:

NO (Normally Open) Mode:

NC (Normally Closed) Mode:

LED indicator on: Misaligned 
or blocked sensor.

LED indicator off: optimal alignment.

        LED indicator blinking: Function used for 
        installation; the blinking LED indicates 
to the installer that the photocell detector 
is sending the signal to the control board and 
it is operating, but it is partially aligned, and 
only needs a simple adjustment for optimal 
alignment and proper operation.

NOTE:

 The slower the LED blinks, the closer to 

the optimal alignment the photocell detector is; 
if the LED starts blinking faster, it is less aligned.

'P' output of the photocell's connection terminal 
connected to the 'FOT' output of the control board
'NA', 'C' and 'NF' outputs of the connection terminal
not connected.

'NF' output of the photocell's connection terminal 
connected to the 'FOT output of the control board

'C' output of the photocell's connection terminal 
connected to the ( - ) output of the control board.

'NA' output of the photocell's connection terminal 
connected to the 'FOT' output of the control board

'C' output of the photocell's connection terminal 
connected to the ( - ) output of the control board.

LED FUNCTIONS

F10R REFLECTIVE PHOTOCELL DETECTOR

INSTRUCTION MANUAL

Step 1: Attach the photocell detector the same side the control 

board is installed, since it will both receive commands from it and 

power it up. The receiver is attached the opposite side, with the 

transmitter and receiver facing each other. When attaching the 

round reflector, mind the (Installation) Position Indicator, it must 

face up.

 (    ). The photocell detector must be attached so 

that the opening for the wiring faces down, in order to 

avoid accidental water entering.

A installation diagram can be seen on the previous page. 

STEP 3: Connect power to the 

sensor by using an auxiliary power 

supply, such as the control board.

Observe the polarity, the wires 

must be connected to the auxiliary 

power supply according to the 

diagrams of the connection 

terminal

.

The height indicated by an “X” refers to the height of the 

possible objects which will be detected by the device, such as 

vehicles, people and pets. For example, for a 50cm (~1.65f) high 

vehicle, the photocell detector must be installed over this 

height, otherwise it will not detect the vehicle. One must 

observe the minimum height (30 cm - ~0.99f), in order to both 

ensure a proper operation and avoid false alarms.

Note:

 There is no maximum height for installing the photocell 

detector.

ATIV/PASS Jumper: This jumper changes the relay operation 

mode.

- Closed: Passive relay (Factory default setting).

- Open: Active relay (In this mode, the relay keeps activated 

while the photocell detector is aligned, i.e., NO mode becomes 

NC and vice versa).

COMFORT AND SECURITY