26
20 - SELECTION OF RF RECEPTION PROTOCOL (CR/CF JUMPER)
Jumper Closed: Fixed Code Protocol
Jumper Open: Rolling Code Protocol
IMPORTANT
Every time this configuration (reception protocol) is changed, ALL the
recorded remote controls MUST be erased. For more information see
topic ‘21’.
21 - ERASING ALL STORED REMOTE CONTROLS
In order to erase all remote controls stored on the board memory, slide the #1 switch of the DS1 DIP switch to the 'ON' position; press
both '-' and '+' buttons of the control board at the same time for 10 seconds, observe that the 'OSC' blinks once per second and after the
10-second period, the LED stops counting the time; this means all added transmitters have been erased.
22 - USER OPERATION
To activate your operator, press for 1 second, the PPA remote button with the machine.
If the remote control is operated while the gate is opening, the gate operator will stop and will remain that way until the remote control
to fire again. When this happens, the gate will close.
Содержание DZ 1500
Страница 1: ...DZ PREDIAL DZ CONDOMINIUM DZ 1500 Technical Manual...
Страница 2: ......
Страница 30: ...30 26 REPAIR PARTS DZ PREDIAL JET FLEX 60HZ U...
Страница 31: ...31...
Страница 32: ...32 DZ CONDOMINIUM JET FLEX 60HZ U...