![PPA DUPLA 5T Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/ppa/dupla-5t/dupla-5t_technical-manual_1592688006.webp)
6
Operation:
1. Gate must be stopped;
2. Close jumper PROG;
3. Press and release the button CMD (5x);
4. Press and release the REC button to enter the function;
5. CMD button to decrement value, or REC to increase value or remove
jumper PROG (Cancel function).
Signage SN led:
Flash 1x = Releasing CMD and / or GRV + button (command accepted).
Flash fast for 1 second = Releasing button CMD (command denied to minimum values).
Lighted for 1 second = Releasing GRV + button (command denied for maximum values).
traffiC sign tiMe (sin)
During the opening or closing cycle of the gate or when it is stopped, the relay
module will be on or swinging.
When the central finalizes the closing cycle, the relay module will shut down.
Values:
0 = on module.
1 = Time oscillation 0,050 the 2nd
2 = Time oscillation 0,100 the 2nd
...
20 = Time oscillation 1,00 second
Operation:
1. Gate must be stopped;
2. Close jumper PROG;
3. Press and release the button CMD (6x);
4. Press and release the REC button to enter the function;
5. CMD button to decrement value, or REC to increase value or remove
jumper PROG (Cancel function).
Signage SN led:
Flash 1x = Releasing CMD and / or GRV + button (command accepted).
Flash fast for 1 second = Releasing button CMD (command denied to minimum values).
Lighted for 1 second = Releasing GRV + button (command denied for maximum values).