Step 6: 

Position the automation vertically on the door column and weld the mounting 

brackets on the column, respecting the measurements in the figure below.

Step 7: 

Attach the drive lever to the pin of the drive nut of the operator.

Step 8: 

Weld the drive lever on the gate leaf, keeping the distance of 250 mm 

between the center of the gate shaft and the center of the lever’s turning point.

110mm (conventional)

80mm (slim)

270 mm

25

0

m

m

ALAVANCA
DE TRAÇÃO

PORCA

ACIONADORA

EIXO DO PORTÃO

PONTO DE GIRO

DA ALAVANCA

Step 9: 

With the gate closed, maintain a 50 mm tilt on the drive lever, respecting 

a distance from the center of the turning point of the drive lever and the center of 

the drive nut pin.

Step 10:

 Still with the gate closed, adjust the closing stop, so that the rubber of 

the gate cushion the drive nut in the closing of the gate. Then, with the gate open, 

perform the same procedure for the opening stop.

ANALOGIC LIMIT SWITCH INSTALLATION

Step 1: 

Position the limit switch magnet into the drive nut housing. Position 

the opening and closing limit switches so that they activate when the gate leaf 

completes its movement. Connect the limit switch to the control unit.

Step 2: 

Place the protective rubber of the wires into the reed housing, traversing 

the entire rail profile.

PORCA

ACIONADORA

REED

IMÃ

TRIGGERING

NUT

TRACTION

LEVER

LEVER
TURNING POINT

GATE AXIS

TRIGGERING
NUT

MAGNET

REED

PIN CENTER OF 

THE TRIGGERING

NUT

TURNING POINT

OF THE DRIVE 

LEVER

Содержание BV LEVANTE

Страница 1: ...cal Manual P30501 08 2022 Rev 0 All images in this manual are for illustrative purposes only Made by Motoppar Ind stria e Com rcio de Automatizadores Ltda Av Dr Labieno da Costa Machado 3526 Distrito...

Страница 2: ...power supply is compatible with that required on the equipment iden tification label Do not connect the electrical grid until ins tallation maintenance is complete Always make electrical connections t...

Страница 3: ...IPX4 IPX4 RAIL Aluminum Steel Aluminum Steel TEMPERATURE RANGE 5 C 50 C 5 C 50 C ISOLATION TYPE Class B 130 C Class B 130 C LIMIT SWITCH Analogic Analogic Digital MAX WEIGHT OF GATE LEAF 200 Kg 300 K...

Страница 4: ...m In the case of push button installations optional fixed control install at a height of at least 1 5 m from the floor and in view of the door further away from moving parts Fix crush risk warning av...

Страница 5: ...leaf Step 2 Remove the top rail cover and install the securing brackets on the opposite side to the drive nut pin Step 3 Insert the closing stop with the rubber facing the drive nut Step 4 Insert the...

Страница 6: ...urning point of the drive lever and the center of the drive nut pin Step 10 Still with the gate closed adjust the closing stop so that the rubber of the gate cushion the drive nut in the closing of th...

Страница 7: ...oes not move A Power off B Open burned fuse C Locked gate D Defective limit switch A Make sure that the power supply is connected correctly B Replace fuse with the same specification C Make sure that...