PPA BV LEVANTE Скачать руководство пользователя страница 3

4

5

4

5

TECHNICAL CHARACTERISTICS

* M

aximum heigh

t is calcula

ted b

y the v

alue obtained in the pr

oduc

t descr

iption (v

alue in met

ers) applied in the equa

tion.

TOOLS REQUIRED FOR INSTALLATION

Here are some tools required to install the automation:

ELECTRICAL GRID

For electrical installation, the network shall contain the following characteristics:

-  Electric network 127 V or 220 V;

-  Have 5 A circuit breakers in the electrical distribution box;

-  3/4 “diameter conduit between the electrical distribution box and the total 

disconnect device;

-  3/4 “diameter conduit between the total shut-off device and the automator’s 

connection point;

-  1/2 “diameter conduits for external and optional push button;

-  Theres of 1/2 “diameter for safety photocells (optional).

PLIERS

HACKSAW

NUT DRIVER

SCREWDRIVER

WRENCH

LADDER

WELDING MACHINE

HAMMER

LEVEL

MEASURING TAPE

SQUARE

DRILLER

PENCIL

SANDER

LEVANTE CUSTOM

LEVANTE

OPERATOR TYPE

OVERHEAD

OVERHEAD

MODEL

Single Phase

Single Phase

RATED VOLTAGE

220 V / 127 V

220 V / 127 V

NOMINAL FREQUENCY

60 Hz

60 Hz

NOMINAL POWER

430 W / 290 W

430 W / 325 W

RPM

1740 RPM

1740 RPM

NOMINAL CURRENT

1,6 A / 2,3 A

2,1 A / 2,9 A

REDUCTION

1:26

1:26

LINEAR SPEED

4,15 m/min

4,15 m/min

MANEUVER

20 cycles/h

30 cycles/h

PROTECTION LEVEL

IPX4

IPX4

RAIL

Aluminum / Steel

Aluminum / Steel

TEMPERATURE RANGE

-5° C / +50° C

-5° C / +50° C

ISOLATION TYPE

Class B, 130° C

Class B, 130° C

LIMIT SWITCH

Analogic

Analogic / Digital

MAX. WEIGHT OF

GATE LEAF

200 Kg

300 Kg

MAX. DIMENSION OF 

THE GATE

*HEIGHT = (Value 

in meters -0,15) x 2 

LENGTH = 4,0 m

*HEIGHT = (Value 

in meters -0,15) x 2 

LENGTH = 4,0 m

LEVANTE SP 

CUSTOM

LEVANTE SP

LEVANTE CUSTOM 

JETFLEX

LEVANTE 

JETFLEX

OPERATOR TYPE

OVERHEAD

OVERHEAD

OVERHEAD

OVERHEAD

MODEL

Single Phase

Single Phase

Jet Flex

Jet Flex

RATED VOLTAGE

127 V / 220 V

220 V / 127 V

220 V / 127 V

220 V / 127 V

NOMINAL FREQUENCY

60 Hz

60 Hz

60 Hz

60 Hz

NOMINAL POWER

280 W / 210 W

435 W / 320 W

380 W

345 W

RPM

1740 RPM

1740 RPM

5800 RPM

5800 RPM

NOMINAL CURRENT

2,5 A / 1,5 A

2 A / 2,8 A

2,8 A / 3,7 A

1,6 A / 3,7 A

REDUCTION

2:30

2:30

2:30

2:30

LINEAR SPEED

7,2 m/min

7,2 m/min

23,9 m/min

23,9 m/min

MANEUVER

20 cycles/h

30 cycles/h

30 cycles/h

40 cycles/h

PROTECTION LEVEL

IPX 4

IPX 4

IPX 4

IPX 4

RAIL

Aluminum / Steel

Aluminum / Steel

Aluminum / Steel

Aluminum / Steel

TEMPERATURE RANGE

-5° C / +50° C

-5° C / +50° C

-5° C / +50° C

-5° C / +50° C

ISOLATION TYPE

Class B, 130° C

Class B, 130° C

Class B, 130° C

Class B, 130° C

LIMIT SWITCH

Analogic

Hybrid

Hybrid

Hybrid

MAX. WEIGHT OF

GATE LEAF

150 Kg

250 Kg

250 Kg

350 Kg

MAX. DIMENSION OF 

THE GATE

*HEIGHT = (Value 

in meters -0,15) x 2 

LENGTH = 4,0 m

*HEIGHT = (Value 

in meters -0,15) x 2 

LENGTH = 4,0 m

*HEIGHT = (Value 

in meters -0,15) x 2 

LENGTH = 4,0 m

*HEIGHT = (Value 

in meters -0,15) x 2 

LENGTH = 4,0 m

Содержание BV LEVANTE

Страница 1: ...cal Manual P30501 08 2022 Rev 0 All images in this manual are for illustrative purposes only Made by Motoppar Ind stria e Com rcio de Automatizadores Ltda Av Dr Labieno da Costa Machado 3526 Distrito...

Страница 2: ...power supply is compatible with that required on the equipment iden tification label Do not connect the electrical grid until ins tallation maintenance is complete Always make electrical connections t...

Страница 3: ...IPX4 IPX4 RAIL Aluminum Steel Aluminum Steel TEMPERATURE RANGE 5 C 50 C 5 C 50 C ISOLATION TYPE Class B 130 C Class B 130 C LIMIT SWITCH Analogic Analogic Digital MAX WEIGHT OF GATE LEAF 200 Kg 300 K...

Страница 4: ...m In the case of push button installations optional fixed control install at a height of at least 1 5 m from the floor and in view of the door further away from moving parts Fix crush risk warning av...

Страница 5: ...leaf Step 2 Remove the top rail cover and install the securing brackets on the opposite side to the drive nut pin Step 3 Insert the closing stop with the rubber facing the drive nut Step 4 Insert the...

Страница 6: ...urning point of the drive lever and the center of the drive nut pin Step 10 Still with the gate closed adjust the closing stop so that the rubber of the gate cushion the drive nut in the closing of th...

Страница 7: ...oes not move A Power off B Open burned fuse C Locked gate D Defective limit switch A Make sure that the power supply is connected correctly B Replace fuse with the same specification C Make sure that...