- The cable for the fixed wiring must comply with NBR NM 247-3;

- The power conductor of a product for internal use must be a 

flexible cable 3 x 0.75 mm²; 500 V, according to the norm NBR NM 

247-5;

- The power conductor of a product for external use must be a 

flexible cable 3 x 0.75 mm²; 500 V, according to IEC 60245-57.

It is mandatory that the ground 

terminal is connected to the 

ground.

IMPORTANT

The device must be powered by a residual current (DR) device, 

with a rated residual current exceeding 30 mA.

PRECAUTIONS WITH THE GATE BEFORE 
AUTOMATION

Before applying the automation to the gate, some procedures should be taken:

-Check the mechanical conditions, whether the balancing is correct and whether 

the opening and closing are suitable. Remove any equipment not necessary for the 

operation of the machine, such as locks, ropes, chains, tools, among others;

-The unlocking (manual release) must be installed at a height of less than 1.8 m;

-In the case of push button installations (optional fixed control), install at a height 

of at least 1.5 m from the floor and in view of the door, further away from moving 

parts;

-Fix crush risk warning, available in the automation kit, in places visible or near the 

button (fixed control);

-Check the manual release system, fastened next to the actuation element of the 

unlocking;

-Move the door leaf manually (opening and closing) and observe the required 

effort. The leaf should rise and fall, throughout the course, with the minimum of 

effort;

-Check the balance of the gate leaf. Lift the sheet up to the middle of the path and 

observe whether it remains stationary. If the sheet remains stationary, the gate will 

be satisfactorily balanced. This equilibrium condition must occur for approximately 

80% of the course, with imbalance close to the extremes of the course being 

permissible.

-The gate shall have a sturdy and, as far as possible, non-deformable structure.

FIXATION AND INSTALLATION OF THE 
OPERATOR

Before installing the automation system, remove any unnecessary 

cables and disable any equipment or system connected to the 

electrical grid.

Содержание BV LEVANTE

Страница 1: ...cal Manual P30501 08 2022 Rev 0 All images in this manual are for illustrative purposes only Made by Motoppar Ind stria e Com rcio de Automatizadores Ltda Av Dr Labieno da Costa Machado 3526 Distrito...

Страница 2: ...power supply is compatible with that required on the equipment iden tification label Do not connect the electrical grid until ins tallation maintenance is complete Always make electrical connections t...

Страница 3: ...IPX4 IPX4 RAIL Aluminum Steel Aluminum Steel TEMPERATURE RANGE 5 C 50 C 5 C 50 C ISOLATION TYPE Class B 130 C Class B 130 C LIMIT SWITCH Analogic Analogic Digital MAX WEIGHT OF GATE LEAF 200 Kg 300 K...

Страница 4: ...m In the case of push button installations optional fixed control install at a height of at least 1 5 m from the floor and in view of the door further away from moving parts Fix crush risk warning av...

Страница 5: ...leaf Step 2 Remove the top rail cover and install the securing brackets on the opposite side to the drive nut pin Step 3 Insert the closing stop with the rubber facing the drive nut Step 4 Insert the...

Страница 6: ...urning point of the drive lever and the center of the drive nut pin Step 10 Still with the gate closed adjust the closing stop so that the rubber of the gate cushion the drive nut in the closing of th...

Страница 7: ...oes not move A Power off B Open burned fuse C Locked gate D Defective limit switch A Make sure that the power supply is connected correctly B Replace fuse with the same specification C Make sure that...