8.2

 

Connecting Cables 

 
Pozyx Anchors can be connected through Ethernet. Each Anchor has 2 RJ45 100Base-T ports. 
They can be used to link up anchors in sequence which reduces the total amount of wiring 
required. We call this Daisy Chaining of Anchors. 
 

 

Figure 2 Pozyx Anchor PoE ports 

 

 

The port labeled “

1

”should be connected to the Positioning 

Gateway. This can 

implemented either by a direct connection to one of the Anchor ports on the 
gateway or by a connection through an Ethernet switch for large setups. 

 

The port labeled “

2

”can be used to connect Anchors in a daisy

-chain. 

 

To create a chain of Anchors connect the port “2” (OUT in the 

figure below) of an Anchor to 

the port “1” (IN in the figure below) of the next Anchor in the chain.

 

 
Pozyx recommends using Ethernet cables that: 

 

Are Pure Copper (Cu). Do not use Copper Clad Aluminum (CCA) 

 

Are Shielded Foil Twisted Pair (S/FTP) 

 

Are Cat5e (or better) 

 

Are AWG24 (or better). Both AWG 24/1 and AWF24/7 are suited. 

Warning:  It is advised not to use crossover Ethernet cables: all Ethernet cables should use 
the T568B wiring specified in the TIA/EIA-568 standard. 
 
Warning:  For system stability it is advised to connect only anchors (and network switches 

solely used to aggregate Anchors) to the ports labeled “Anchor network” on the gateway.

 

 
 

 

Содержание Anchor V2.2

Страница 1: ...1 Accurate Positioning Anchor V2 2 USER MANUAL v1 0 2022 01 25...

Страница 2: ...nchor 9 8 4 Anchor Headers 10 8 4 1 Mounting the IP66 67 header 11 8 4 2 Mounting the IP20 header 12 8 5 Best Practices for Anchor Placement 12 8 5 1 Specific guidelines for 2D positioning 13 8 5 2 Sp...

Страница 3: ...nt follows all safety and operational instructions Under no circumstances should this equipment be used if the equipment is faulty or the operator does not completely understand the operation of the e...

Страница 4: ...Copyright All rights reserved No part of this document may be reproduced or transmitted in any way or shape be it electronic mechanical photocopying recording or otherwise without the express prior wr...

Страница 5: ...rise System Architecture The Pozyx architecture comprises three main parts A network of anchors and tags This network consists of two types of devices tags and anchors The tag is a mobile device used...

Страница 6: ...ssure Supply Voltage Temperature Power supply POE POE or DC 6 to 53V 4 5W max Dimensions 157 x 98 x 53 mm Weight 170 g Ingress protection IP20 or IP66 67 with add on header Operating conditions 25 C t...

Страница 7: ...7 VESA wall mount 90 020 0002 VESA ceiling mount 90 020 0003 The Anchor is mounted with 4 x M4 screws on the mounting bracket...

Страница 8: ...e used to connect Anchors in a daisy chain To create a chain of Anchors connect the port 2 OUT in the figure below of an Anchor to the port 1 IN in the figure below of the next Anchor in the chain Poz...

Страница 9: ...o the port labeled 1 Remark In general 4 5 anchors depending on the installation setup and environment and taking the conditions into consideration is the maximum for a chain when powered through a Po...

Страница 10: ...and IP67 ingress protection to the Anchor The Ethernet cables enter the Header sideways The header 90 011 0001 can optionally be used to guide the external cables The ingress protection level of this...

Страница 11: ...e Ethernet cable 3 Place the grommets over the Ethernet cable 4 Pull the Ethernet cable thru the cable glands 5 Plug the Ethernet connectors into the correct RJ45 jack Route the Ethernet cables in a c...

Страница 12: ...hernet cable without pre confectioned connectors Warning Make sure that the RJ45 connectors are suited for the deployed Ethernet cable 2 Pull the Ethernet cables and the DC power cable if used through...

Страница 13: ...g error will can be very large A small change in radius for example due to noise will result in a very large change in the position of the intersection s Make sure each anchor sees at least two but pr...

Страница 14: ...installation setup anchors setup rollout installing the anchors for the latest guidelines 8 6 Anchor Activation 8 6 1 UWB functionality The general description of the Anchor setup and configuration a...

Страница 15: ...eral malfunction Solid blue Startup or Maintenance mode Solid red No Ethernet link Blinking orange Link on Ethernet interface established Solid orange IP address obtained Blinking Green Anchor operati...

Страница 16: ...end of their working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsib...

Страница 17: ...is own expense Radiation Exposure Statement The device complies with the requirements set forth in CFR 47 Sections 2 1091 for an uncontrolled environment The antennas used for this transmitter must be...

Страница 18: ...010 IEC IEEE 62209 1528 2020 Article 3 1b EMC CISPR 32 2015 AMD1 2019 EN 301 489 1 V2 2 3 2019 11 EN 301 489 17 V3 2 4 2020 09 EN 301 489 33 V2 2 1 2019 04 EN 61000 4 2 2009 EN 61000 4 3 2020 EN 61000...

Отзывы: