Table 1. Dimensions

3

Model

A

B

C

D

E

F

G

H

J

M

OUH 20

F

555

610

100

465

101

549

410

K

370

340

L

85

OUH 30, 

45 & 60

270

MAXIMUM 

DUCT

RESISTANCE

Table 2 - Specifications

  MODEL

INPUT

(Net)

OUTPUT

kg

kW

m³/s

Pa

kW

OUH20

21.92

20.0

0.2601

OUH 30

32.15

30.0

0.3902

OUH 45

49.40

45.0

0.5203

OUH 60

65.57

60.0

0.6503

N/A

0.040

53

140

0.250

91.5

N/A

0.120

126

187

0.750

142

N/A

0.412

126

100

0.750

142

N/A

0.412

126

50

0.750

142

F

C

F

C

F

C

F

C

HIGH FIRE

AIR

VOLUME

FAN

MOTOR

WEIGHT

NOISE

LEVEL

dB(A) @ 3m

N/A

N/A

N/A

N/A

46

54

52

53

Type

C

F

C

668

N/A

N/A

780

847

125

490

276

490

494

270

975

636

418

165

N/A

N/A

N/A

N/A

N/A

N/A

Note:

 D is the nominal flue diameter.

THROW

8.5

16.1

25.3

34.1

N/A

N/A

N/A

N/A

Table 4 Burner Settings - 35sec Oil - Net CV (H

i

) = 42.69MJ/kg

   

 

 

 

  Riello Burners

   

 

 

Nozzle   

 

Pump  Head Setting  Combustion 

Nominal

  Model 

Type 

Make 

Size 

Angle  Type  Pressure  No.  Postion  Air Setting 

CO

2

%

   

 

 

US Gal 

° 

 

bar

  OUH 20 

3GB 

Danfoss 

0.50 

60 

9.5 

N/A  Fixed 

2.0  

12.5

  OUH 30 

G10 

Danfoss 

0.60 

45 

14.3 

1.0 

N/A 

1.5  

12.8

  OUH 45 

G10 

Danfoss 

1.00 

45 

12.2 

3.0 

N/A 

2.0  

12.0

  OUH 60 

G10 

Danfoss 

1.25 

45 

15.6 

3.0 

N/A 

5.0  

12.0

Table 3

Electrical Loadings 1ph

/F Models

/C Models

MODEL

PLATE

AMPS

(A)

START

AMPS

(A)

RUN

AMPS

(A)

FUSE

RATING

(A)

OUH 20

2

OUH 30

0.18

0.34 0.16

2.8

4.2

2.10

1.40 0.90

4.0

15.0 7.0

OUH 45

4.50 1.00

4.0

15.0

7.0

3

NOMINAL

MOTOR

R.P.M.

PLATE

AMPS

(A)

START

AMPS

(A)

RUN

AMPS

(A)

FUSE

RATING

(A)

OUH 60

4.50 1.00

0.54

0.89

0.31

4.0

15.0 7.0

900

1400

5

920

kg/h

1.85

2.71

4.16

5.53

FUEL

INPUT

m

Содержание OUH series

Страница 1: ...Users Installation and Servicing Instructions WARNING THIS APPLIANCE MUST BE EARTHED CE OUH Range Users Installation Servicing Instructions Issue 4 March 2010 The OUH Range...

Страница 2: ...s and local regulations 2 The appliance has been professionally commissioned 3 The appliance has been maintained on a yearly basis by a competent servicing company 4 The appliance has been used in acc...

Страница 3: ...5 minutes later the heater fan will automatically stop 4 1 Summer Winter Modes Certain types of external controls will provide for two modes of operation i e Summer The heater fan alone will run at th...

Страница 4: ...n of Heater 5 5 Air Distribution System 7 6 Commissioning Testing 7 7 Servicing 7 8 Wiring Diagram 9 9 Short List of Parts 9 Figure Title Page 1 Limit Thermostat 8 Table Title Page 1 Dimensions 3 2 Sp...

Страница 5: ...s The OUH F has an axial type fan assembly fitted at the rear of each heater to circulate the air being heated across the combined combustion chamber heat exchanger A centrifugal fan variation is pres...

Страница 6: ...0 F OUH20 C Rear View E F F D A K Side View B C M Front View Rear View L 50mm Side View J H G Front View OUH30 45 60 C OUH30 45 60 F Rear View E F D A K Side View B C M Front View Rear View 50mm L Sid...

Страница 7: ...l flue diameter THROW 8 5 16 1 25 3 34 1 N A N A N A N A Table 4 Burner Settings 35sec Oil Net CV Hi 42 69MJ kg Riello Burners Nozzle Pump Head Setting Combustion Nominal Model Type Make Size Angle Ty...

Страница 8: ...t 2 Particular attention is drawn to the following a Pipe jointing compounds must be capable of withstanding the solvent action of the fuel oil under all operating temperatures and pressures Jointing...

Страница 9: ...Rating Air Vent Area of Air Heaters Air direct from outside Up to 60kW 4 5 cm kW in excess of 7kW From 60kW up to 730kW 4 5 cm kW Where the air heater is to be installed in a plant room the heater re...

Страница 10: ...inal connection of the incoming mains supply and completion of the control circuit 230V via a room thermostat time clock etc All units must be earthed The electrical supply must be run to a point adja...

Страница 11: ...a Powrtrol or MC200 is being used that the Winter mode is selected 6 5 Lighting the Air Heater Refer also to the burner instruction booklet 1 Remove the burner cover after releasing the three retainin...

Страница 12: ...ur hexagon headed bolts that secure the fan to the rear panel 6 Reassemble in reverse order 7 5 2 Centrifugal Fan 1 Inspect the fan blades to see that they are not damaged and that there is no build u...

Страница 13: ...ue Brown Black Gr Yellow MAIN FAN CAPACITOR VENT VENT CLOCK O P HEAT IN HEAT OUT L N POWRTROL Additional Oil Valve 8 Wiring Diagram 9 Short List of Parts Only originally specified parts may be fitted...

Страница 14: ...rovement we reserve the right to alter specifications without prior notice HEATING DIVISION Hort Bridge Ilminster Somerset TA19 9PS Tel 01460 53535 Fax 01460 52341 BSI Registered Firm FM 414 Ind Comm...