Powr-Flite PFX900S Скачать руководство пользователя страница 8

8

MAINTENANCE GUIDE

CAUSE

SOLUTION

1) Power not reaching main switch.

1) Check power supply. Check fuses/circuit  breaker.  

Contact service center

2) Defective power cord.

2) Replace with 14 gauge cord.

3) Faulty switches or wiring.

3) Contact manufacturer or service center.

4) Blown fuse or tripped circuit breaker

4) Reset circuit breaker according to operating

5) Problem with brushes, field windings, 

    or armatures. (vacuum or brush motor)

5) Contact manufacturer or service center.

CAUSE

SOLUTION

1) Vacuum head blocked.

1) Visually inspect and clear blockage.

2) Hoses blocked.

2) Visually inspect and clear blockage.

3) Recovery tank not sealed properly.

3) Check tank for damage or adjust lid for proper fit.

CAUSE

SOLUTION

1) Belt broken.

1) Replace belt.

2) Brush jammed.

2) Visually inspect and clear blockage.

3) Bearing seized.

3) Contact manufacturer or service center.

CAUSE

SOLUTION

1) Jet blocked.

1) Visually inspect and clean according to  

    

operating instructions.

2) Solution filter blocked.

2) Visually inspect and clean according to  

    

operating instructions.

3) Pump head, valves or diaphragm blocked 

or damaged.

3) Contact manufacturer or service center.

4) Solenoid valve inoperative

4) Contact manufacturer or service center.

 Motors not running

Loss of vacuum suction

 Brush not functioning properly

 Spray jet not functioning properly

Содержание PFX900S

Страница 1: ...ET EXTRACTOR PFX900S PFX900S MAN 03 2020 OPERATOR S MANUAL WARNING OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT Tacony Corporation All rights reserved Save...

Страница 2: ...____________________________ Serial Number ____________________________________________________________________________ Date of Purchase _______________________________________________________________...

Страница 3: ...this extractor It is important to follow instructions in this manual to prevent the possibility of injury or damage to the user and or machine 115 VAC GROUNDING INSTRUCTIONS This unit must be grounded...

Страница 4: ...et hands 11 Extension cord must be a three wire type 14 gauge or larger to ensure grounding protection 12 Do not put any object into openings 13 Do not use with any opening blocked keep free of dust l...

Страница 5: ...ght 100 lbs 45 kg 100 lbs 45 kg Voltage 115 VAC 230 VAC GENERAL INSTRUCTIONS PRE OPERATION INSTRUCTIONS NOTE color fastness Before using carpet cleaning chemicals test on an inconspicuous part of the...

Страница 6: ...aximum is recommended to avoid overwetting After a few passes check the waste tank to see that no foam is present Add extra defoamer if necessary 5 Make sure to empty the recovery top tank when it is...

Страница 7: ...vacuum head brush and brush housing 3 Always wash out the tanks with clean water after use To do this pour clean water into the solution tank and spray through spray tip to clear chemical residue fro...

Страница 8: ...blocked 2 Visually inspect and clear blockage 3 Recovery tank not sealed properly 3 Check tank for damage or adjust lid for proper fit CAUSE SOLUTION 1 Belt broken 1 Replace belt 2 Brush jammed 2 Visu...

Страница 9: ...A Tacony Company 3101 Wichita Court Fort Worth TX 76140 1755 1 800 880 2913 Fax 1 817 551 0719 PFX900S MAN 03 2020 For warranty information go to www Powr Flite com...

Отзывы: