READ ALL INSTRUCTIONS BEFORE USING!

Congratulations on purchasing this self-contained extractor.  Given proper care, this product 
will afford you many years of trouble-free operation.  All parts have passed rigid quality control 
standards before being assembled to produce the finished product. 

Prior to packaging, the extractor is again inspected for assurance of flawless assembly.  This 
unit is protectively packed to prevent damage in shipment.  We recommend removal and 
inspection of unit upon delivery for possible damage in transit.  Only a visual examination 
will reveal damage that may have occurred. If damage is discovered, immediately notify the 
transportation company that delivered your extractor.  As a shipper, we are unable to report 
claims for concealed damage.  You must originate any claim within 5 days of delivery.

This manual is for your protection and information.  

PLEASE READ CAREFULLY 

since failure to 

follow precautions could result in discomfort or injury.  When using electrical equipment, basic 
safety precautions should always be followed.

CARE OF THIS SELF-CONTAINED EXTRACTOR

Treat this unit as you would any other high grade precision made product.  Dropping, 
unreasonable bumping across thresholds and other misuses may result in a damaged unit 
which will not be covered by warranty.  When not in use, power cord should be wrapped around 
handle for storage.  Read this manual completely before operating this extractor.  It is important 
to follow instructions in this manual to prevent the possibility of injury or damage to the user 
and/or machine.

115 VAC GROUNDING INSTRUCTIONS

This unit must be grounded! Grounding is a safety measure to reduce the risk of electrical 

shock to the operator should the machine malfunction or stop working. Grounding provides 

the path of least resistance for electric current and will trip the circuit breaker, stopping the 

flow of electricity.
This unit is equipped with a cord containing an equipment-grounding conductor and 

grounding plug. The plug must be inserted in an appropriate outlet that is properly installed 

and grounded in accordance with all local codes and ordinances. Cutting off the ground wire 

or using a cord that is not equipped with a ground plug will void the warranty on the unit. 

Manufacturer will accept NO liability associated with the unit.

Improper connection of the equipment-grounding conductor can result in a risk of electric 

shock. Check with a qualified electrician or service person if you are in doubt as to whether 

the outlet is properly grounded. Do not modify the plug provided with the appliance. If it will 

not fit the outlet, have a proper outlet installed by a qualified electrician.

This Extractor is for use on a nominal 115-Volt circuit, and has a grounded plug that looks like 

the plug illustrated in Figure A.

GROUNDING

PIN

GROUNDING

OUTLET

GROUNDED

OUTLET BOX

Figure A

The replacement or repair of damaged wiring should only be performed by a 

qualified electrician or service engineer from the manufacturer or authorized 

service center.

WARNING

Содержание PFX900S

Страница 1: ...ET EXTRACTOR PFX900S PFX900S MAN 03 2020 OPERATOR S MANUAL WARNING OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT Tacony Corporation All rights reserved Save...

Страница 2: ...____________________________ Serial Number ____________________________________________________________________________ Date of Purchase _______________________________________________________________...

Страница 3: ...this extractor It is important to follow instructions in this manual to prevent the possibility of injury or damage to the user and or machine 115 VAC GROUNDING INSTRUCTIONS This unit must be grounded...

Страница 4: ...et hands 11 Extension cord must be a three wire type 14 gauge or larger to ensure grounding protection 12 Do not put any object into openings 13 Do not use with any opening blocked keep free of dust l...

Страница 5: ...ght 100 lbs 45 kg 100 lbs 45 kg Voltage 115 VAC 230 VAC GENERAL INSTRUCTIONS PRE OPERATION INSTRUCTIONS NOTE color fastness Before using carpet cleaning chemicals test on an inconspicuous part of the...

Страница 6: ...aximum is recommended to avoid overwetting After a few passes check the waste tank to see that no foam is present Add extra defoamer if necessary 5 Make sure to empty the recovery top tank when it is...

Страница 7: ...vacuum head brush and brush housing 3 Always wash out the tanks with clean water after use To do this pour clean water into the solution tank and spray through spray tip to clear chemical residue fro...

Страница 8: ...blocked 2 Visually inspect and clear blockage 3 Recovery tank not sealed properly 3 Check tank for damage or adjust lid for proper fit CAUSE SOLUTION 1 Belt broken 1 Replace belt 2 Brush jammed 2 Visu...