background image

 

 

D0136 RevC 

C19-01-01 

 

INSTRUCTION SHEET

 

Model PA6 Family

 

Air/Hydraulic Pump 10,000 PSI Capacity

 

Safety/Warning - Set-up - Operating - Maintenance Instructions 

 

IMPORTANT - READ CAREFULLY 

This manual contains important information about the correct installation, operation and maintenance 
of this equipment. All persons involved in the installation, operation and maintenance of this equipment 
must be thoroughly familiar with the contents of this manual. To safeguard against the possibility of 
personal injury or property damage, follow the recommendations and instructions of this manual. Keep 
this manual for reference. 

WARRANTY STATEMENT 

PowerX products are warranted to be free of defects in materials and workmanship under normal use, 
please go to www.powerxinternational.com to review our complete warranty policy. This warranty does 
not cover: normal wear & tear, cosmetic items, abuse, overloading, alterations, improper lubrication, or 
use in a manner for which they are not intended. If the customer believes a product is defective, the 
product must be delivered, or shipped freight prepaid, to the nearest PowerX Authorized Service Center 
for evaluation and repair. 

RECEIVING INSTRUCTIONS 

Important! Make sure to inspect all of the components for shipping damage. If damage is found, notify 
carrier at once. Shipping damage will not be covered by warranty. The carrier is responsible for all loss 
associated with shipping damage. 

CONTENTS

 

 

SECTION 

Receiving Instructions ...............................................................................................................................1.0 
Safety ........................................................................................................................................................2.0 
Technical Specifications ............................................................................................................................3.0 
Basic Operation and Function ...................................................................................................................4.0 
Basic Operation .........................................................................................................................................4.1 
After Completing the Job ..........................................................................................................................4.2 
Periodic Maintenance ...............................................................................................................................5.0 
Maintain Oil Level .....................................................................................................................................5.1 
Troubleshooting ........................................................................................................................................6.0 
 

 

 

Содержание PA6 Series

Страница 1: ...al use please go to www powerxinternational com to review our complete warranty policy This warranty does not cover normal wear tear cosmetic items abuse overloading alterations improper lubrication or use in a manner for which they are not intended If the customer believes a product is defective the product must be delivered or shipped freight prepaid to the nearest PowerX Authorized Service Cent...

Страница 2: ...ay cause serious injury or even death WARNING indicates a potential danger that requires correct procedures or practices to avoid personal injury CAUTION is used to indicate correct operating or maintenance procedures and practices to prevent damage to or destruction of equipment or other property WARNING Wear proper personal protective gear when operating hydraulic equipment WARNING The system op...

Страница 3: ...31 82 13 60 150 32 PA6 122D D A Valve 122 82 13 60 150 22 PA6 231D D A Valve 231 82 13 60 150 32 PA6 460D D A Valve 460 82 13 60 150 44 4 0 BASIC OPERTION AND FUNCTION 1 Locate and remove the shipping plug and discard Ensure the oil level is just below the oil filler plug hole see the chart in section 5 B Install the vent oil fill dip stick plug 2 Remove air inlet shipping plug and discard Pour a ...

Страница 4: ...see figure 1 5 To retract a cylinder simply press down on the RELEASE valve or pendant button portion of the pump Fully depressing pedal will LOCK the DETENT feature to on see figure 1 6 For double acting pumps model D to build pressure depress were indicated see figure 1 When the handle is in the center position the load will not move even if the pump is running To actuate the load start the pump...

Страница 5: ... from the top of the fill hole Model Recommended Oil Level from the Top of Fill Hole Minimum Fill Lever Maximum Fill Level PA6 98C PA6 122 PA6 98R PA6 122D 1 25 5 PA6 231 PA6 231D PA6 460D 2 25 1 5 4 Use PowerX oil only Model PL 1 1 gallon Using oil other than PowerX Brand may void the pump warranty 5 Wipe up any spilled fluid and install oil filler screw 6 Return pump to original position paralle...

Страница 6: ...r empty or low Check oil level once the tooling is fully retracted should be from top see 5 B above of oil tank cover or check that your tooling requirement does not exceed the foot pump oil capacity Defective coupler not allowing flow Coupler is not fully seated or ball seats are defective replace coupler Oil entrance valve clogged Oil inlet is clogged with foreign matter or seat is defective UNI...