background image

 

 

D0136 RevC 

C19-01-01 

 

1. Inspect hose and connections daily. Replace damaged components immediately with PowerX 
Authorized replacement parts only. 

2. Tighten connections as needed. Use pipe thread Teflon when servicing connections. NOTE: 
DO NOT OVER TIGHTEN CONNECTIONS. 

3. When not in use or during storage: 

• Disconnect pump from air source, depressurize and disconnect hydraul

ic hoses from 

application. 

• Wipe clean, throughout.

 

• Shelter the pump with protective cover.

 

• Store in clean, dry environment.

 

• Avoid temperature extremes.

 

B) HOW TO FILL THE RESERVOIR 

1. Disconnect hydraulic hose from application, remove air source from pump. 

2. With reservoir horizontal, remove the vent / oil filler plug. 

3. Use a small funnel to fill reservoir so the oil level remains the distance stated below in the 
table, distances are measures from the top of the fill hole. 

Model 

Recommended Oil Level from the Top of Fill Hole 

Minimum Fill Lever 

Maximum Fill Level 

PA6-98C, PA6-122, PA6-98R, PA6-122D 

1.25" 

.5" 

PA6-231, PA6-231D, PA6-460D 

2.25" 

1.5" 

 

4. Use PowerX oil only (Model PL-1, 1 gallon). Using oil other than PowerX Brand may void the 
pump warranty. 

5. Wipe up any spilled fluid and install oil filler screw. 

6. Return pump to original position (parallel to a flat level surface), reconnect application and air 
source. Operate for a few seconds, and then check for leaks. 

C) CHANGING THE OIL 

1. For best results, change fluid once a year. 

2. Repeat steps (B) “How to Fill Reservoir”, and then pour used fluid into a sealable container.

 

3. Fill with PowerX oil. Reinstall oil filler plug. 

D) LUBRICATION (When no in-line oiler is used) 

1. When used daily, pour a teaspoon of good quality air tool oil #10 non-detergent oil into the 
air source inlet of pump. Connect hydraulic hose to application, connect air source to pump and 
operate pump a few seconds to evenly distribute fluid. 

Содержание PA6 Series

Страница 1: ...al use please go to www powerxinternational com to review our complete warranty policy This warranty does not cover normal wear tear cosmetic items abuse overloading alterations improper lubrication or use in a manner for which they are not intended If the customer believes a product is defective the product must be delivered or shipped freight prepaid to the nearest PowerX Authorized Service Cent...

Страница 2: ...ay cause serious injury or even death WARNING indicates a potential danger that requires correct procedures or practices to avoid personal injury CAUTION is used to indicate correct operating or maintenance procedures and practices to prevent damage to or destruction of equipment or other property WARNING Wear proper personal protective gear when operating hydraulic equipment WARNING The system op...

Страница 3: ...31 82 13 60 150 32 PA6 122D D A Valve 122 82 13 60 150 22 PA6 231D D A Valve 231 82 13 60 150 32 PA6 460D D A Valve 460 82 13 60 150 44 4 0 BASIC OPERTION AND FUNCTION 1 Locate and remove the shipping plug and discard Ensure the oil level is just below the oil filler plug hole see the chart in section 5 B Install the vent oil fill dip stick plug 2 Remove air inlet shipping plug and discard Pour a ...

Страница 4: ...see figure 1 5 To retract a cylinder simply press down on the RELEASE valve or pendant button portion of the pump Fully depressing pedal will LOCK the DETENT feature to on see figure 1 6 For double acting pumps model D to build pressure depress were indicated see figure 1 When the handle is in the center position the load will not move even if the pump is running To actuate the load start the pump...

Страница 5: ... from the top of the fill hole Model Recommended Oil Level from the Top of Fill Hole Minimum Fill Lever Maximum Fill Level PA6 98C PA6 122 PA6 98R PA6 122D 1 25 5 PA6 231 PA6 231D PA6 460D 2 25 1 5 4 Use PowerX oil only Model PL 1 1 gallon Using oil other than PowerX Brand may void the pump warranty 5 Wipe up any spilled fluid and install oil filler screw 6 Return pump to original position paralle...

Страница 6: ...r empty or low Check oil level once the tooling is fully retracted should be from top see 5 B above of oil tank cover or check that your tooling requirement does not exceed the foot pump oil capacity Defective coupler not allowing flow Coupler is not fully seated or ball seats are defective replace coupler Oil entrance valve clogged Oil inlet is clogged with foreign matter or seat is defective UNI...