background image

THANK YOU 

 

Thank you for your purchase of this power conditioning solution.  Our broad 

family of power conditioning products is designed to protect sensitive electronic 
systems from the destruction, degradation, and disruption caused by electrical 
power disturbances.   

The model you have purchased is designed for use with a wide variety of 

electronic systems including terminals, workstations, LAN servers, 
telecommunications KEY and PBX systems, point of sale systems, medical 
instrumentation, programmable logic controllers, digital control systems and many 
others. 

 

 

INSPECTION 

 

Remove the power conditioner from the shipping container and inspect it for 

shipping damage.  Do not install or operate the product if it appears to be damaged 
in any way.  If damaged, notify the carrier and the company that sold it to you 
immediately. 

 

 

ENVIRONMENTAL ISSUES

 

 

This power conditioner has environmental requirements similar to other 

computer and electronic equipment.  It has been designed for indoor use only, in 
areas where it will not be exposed to excessive dust or moisture.  Make certain that 
there is adequate airflow around the unit.  If the unit has air vents, do not place 
objects on top of or near the unit in such a way as to block the vents. 
 
 

TECHNICAL AND SERVICE ASSISTANCE 

 

Technical and service assistance is available in North America between the 

hours of 8:00 a.m. and 5:00 p.m. Central Time by calling 800-369-7179 (in Illinois, 
call 847-596-7000).  In EMEA, contact POWERVAR at +44 (0) 1793 553980. 

Technical and/or service problems and/or questions may also be placed with 

POWERVAR at our website at www.powervar.com.  Click on “SERVICE” and follow 
the appropriate link. 
 
 

CUSTOMER SERVICE 

 

For service, obtain the model number, part number, and serial number from the 

rear panel data plate.  Then contact POWERVAR via phone or web to obtain a 
Return Material Authorization (RMA) number.  This number must be marked on the 
shipping container and packing slip of the unit being returned.  The original shipping 
container should be used if available.  Additional charges will apply for repair of 
damages caused by improper packing of the returned unit.  Unauthorized return 
shipments will be refused.  Units for repair must be shipped prepaid to POWERVAR. 

 
 

Содержание ABC10.0-2S

Страница 1: ...er s Guide Industrial Conditioners GPI Series B Conditioners GPI Series 1 Conditioners 2 15 kVA Single Phase Conditioners GPI Series 1 Conditioners POWERVAR Single Phase Power Conditioners RoHS Compliant ...

Страница 2: ...hanges may periodically be made to the information herein and such changes may be incorporated in new editions of the product and it s accompanying documentation without obligating POWERVAR to update information and or product that has been delivered earlier POWERVAR assumes no liability for typographical errors in this documentation POWERVAR shall not be liable for technical or editorial errors o...

Страница 3: ...ill not be exposed to excessive dust or moisture Make certain that there is adequate airflow around the unit If the unit has air vents do not place objects on top of or near the unit in such a way as to block the vents TECHNICAL AND SERVICE ASSISTANCE Technical and service assistance is available in North America between the hours of 8 00 a m and 5 00 p m Central Time by calling 800 369 7179 in Il...

Страница 4: ...eu of all other warranties No greater degree of liability is imposed on the manufacturer INSTALLATION AND OPERATING INSTRUCTIONS Please consult Appendix A for installation and operating instructions on the following models ABC360 91IND ABC750 91IND ABC1000 91IND ABC1500 91IND Please consult Appendix B for installation and operating instructions on the following models ABC500 91BUI ABC1000 91BUI AB...

Страница 5: ...time of order the power conditioner has been set during manufacture by the factory for a 480 volt input The input voltage of the power conditioner is selectable from 480 240 208 or 120 volts and may be changed by moving the jumpers on BOTH TB2 and TB3 See Figure 1 that follows for proper jumper positioning and an example of how the conditioner may be rewired When connections are completed replace ...

Страница 6: ...Figure 1 INDUSTRIAL POWER CONDITIONERS ...

Страница 7: ...pre configured by the factory for a 120 volt input Series 1 power conditioners are ordered for a specific input voltage and the circuit breaker installed in the unit is the correct one for the selected operating voltage The input voltage of both the GPI Series B and Series 1 can be set to 100 120 208 or 240 volts by changing jumpers on terminal block TB1 as shown in Figure 2 Series B power conditi...

Страница 8: ...013 25 H 5 00 JA2S A38 A 0005 25 H 15 25 JA2S A38 A 1525 25 H 5 50 JA2S A38 A 05R5 25 H 15 50 JA2S A38 A 1550 25 H 6 50 JA2S A38 A 06R5 25 H 17 00 JA2S A38 A 1700 25 H 7 75 JA2S A38 A 7R75 25 H 20 50 JA2S A38 A 2050 25 H 8 50 JA2S A38 A 08R5 25 H 25 50 JA2S A38 A 2550 25 H 8 75 JA2S A38 A 8R75 25 H 30 50 JA2S A38 A 3050 25 H 10 25 JA2S A38 A 1025 25 H OPERATING INSTRUCTIONS GPI Series B Complete a...

Страница 9: ...Figure 2 INPUT VOLTAGE ADJUSTMENT GPI SERIES B AND GPI SERIES 1 ABC500 XX ABC1000 XX ABC1500 XX ABC2000 XX ABC3000 XX ...

Страница 10: ...are accessed by removing the knockouts on the back panel Terminal blocks are designed to accept a maximum wire size of 8 AWG and 8 foot pounds of torque All applicable electrical codes must be observed for the installation of this device When wiring connections are complete replace the cover before applying power to the power conditioner OPERATING INSTRUCTIONS If power was turned off at the panel ...

Страница 11: ...input move circuit breaker lead from point E2 of the printed circuit filter assembly to point E3 To convert 240 volt input to 208 volt input move circuit breaker lead from point E3 of the printed circuit filter assembly to point E2 Factory default setting is 240 volt input unless specified differently at time of order with factory ...

Страница 12: ...on on models ending with suffix 2S only adjust taps on left side of transformer when viewed from rear of conditioner Moving taps permits changing of input operating voltage between 208 and 240 volts Input voltage adjustment taps this side of transformer ...

Страница 13: ...se SM503 RevC 11 23 04 2004 POWERVAR Inc In North America South America and the Caribbean 1450 Lakeside Drive Waukegan IL 60085 Phone 847 596 7000 Toll Free outside Illinois only 800 369 7179 Fax 847 596 7100 In EMEA Unit 5 Birch Kembrey Park Swindon Wiltshire SN2 8UU United Kingdom Phone 44 0 1793 553980 Fax 44 0 1793 535350 Access additional product information and support on the web at http www...

Отзывы: