background image

4

ASSEMBLY

POWER SOURCE

     WARNING

Do not connect to the power source until the machine is 
completely assembled.
The machine is wired for 120 volts, 60 HZ alternating 
current. Before connecting the machine to the power 
source, make sure the switch is in the “OFF” position. 
Running the unit on voltages which are not within range 
may cause overheating and motor burn-out. Heavy loads 
require that voltage at motor terminals be no less than the 
voltage specified on nameplate.

GROUNDING INSTRUCTIONS

     WARNING

Improper connection of equipment grounding conductor 
can result in the risk of electrical shock.

  The machine should be grounded while in use to protect 

operator from electrical shock.

• 

 In the event of an electrical short circuit, grounding 

reduces the risk of electrical shock by providing an 
escape wire for the electric current.

• 

 This machine is equipped with an approved 3-conductor 

cord rated at 120V and a 3-prong grounding type plug 
for your protection against shock hazards.

• 

 Grounding plug should be plugged directly into a 

properly installed and grounded 3-prong grounding-type 
receptacle, as shown (Figure 3).

Figure 3

Properly Ground Outlet Box

3-Prong Plug

Grounding Prong

• 

 The plug must be plugged into an outlet that is properly 

installed and grounded in accordance with all local 
codes and ordinances.

• 

 Check with a qualified electrician or service personnel if 

these instructions are not completely understood or if in 
doubt as to whether the tool is properly grounded.

• 

 Do not modify plug provided. If it will not fit in outlet, 

have a  proper outlet installed by a qualified electrician. 
Use only 3-wire extension cords, that have 3-prong 
grounding type plugs and matching 3-conductor 
receptacles that accept the machine’s plug, as show in 
Figure 3.

     WARNING

Do not permit fingers to touch the terminals of plug when 
installing or removing from outlet.

• 

 Inspect tool cords periodically, and if damaged, have it  

  repaired by an authorized service facility.

• 

 The conductor with insulation having an outer surface 

that is green with or without yellow stripes is the 
equipment-grounding conductor. If repair or replacement 
of the electric cord or plug is necessary, do not connect 
the green (or green and yellow) wire to a live terminal. 

  A temporary 3-prong to 2-prong grounding adapter 

(see Figure 4) may be used to connect this plug to a 
matching 2-conductor receptacle as shown in figure 8. 
The temporary adapter should be used only until a 
properly grounded outlet can be installed by a qualified 
electrician.

Grounded Lug

Adapter

3-Prong Plug

Make Sure This 

is Connected to a 

Known Ground

2-Prong Receptacle

Figure 4

In Canada, the use of temporary adapter is not permitted 
by the Canadian Electric Code. Where permitted, the rigid 
green tab or terminal on the side of the adapter must be 
securely connected to a permanent electrical ground such 
as a properly grounded water pipe, a properly grounded 
outlet box or a properly grounded wire system.

  Many cover plate screws, water pipes and outlet boxes 

are not properly grounded. To ensure proper grounding 
means that it must be tested by a qualified electrician.

EXTENSION CORDS

Use proper extension cords. Make sure the extension 
cord is in good condition. Use only 3-wire extension 
cords that have 3-prong grounding type plugs and 3-pole 
receptacles which accept the tool plug. When using an 
extension cord, make sure to use one heavy enough to 
carry the current of the machine. An undersized cord will 
cause a drop in the voltage, resulting in loss of power and 
overheating. Use the table to determine the minimum wire 
size (A.W.G.) Extension cord.

Extension Cord Length

Wire Size…………….. A.W.G.
Up to 25 ft…………… 16 gauge

NOTE:

 Using extension cords over 25 ft. long is not 

recommended.

Содержание BF601

Страница 1: ...need this manual for safety instructions operating procedures and warranty Put it and the original sales invoice in a safe dry place for future reference Visit us on the web at powertecproducts com QUESTION 21 0504 6 Heavy Duty Bench Buffer ...

Страница 2: ... CONTENTS SAFETY RULES 1 Work Preparation Work Area Preparation Tool Maintenance Tool Operation ASSEMBLY 3 OPERATION 5 MAINTENANCE 5 TROUBLESHOOTING 6 PARTS ILLUSTRATION LIST 8 WARRANTY 10 SECTION PAGE Unpacking Tools Needed Set Up Power Source Grounding Instructions Extension Cords Basic Operation General Maintenance Cleaning SPECIFIC SAFETY RULES 2 ...

Страница 3: ...orkshop childproof with padlocks master switches or remove switch keys to prevent any unintentional use of power tools WARNING TOOL MAINTENANCE Turn the machine OFF and disconnect the machine from the power source prior to inspection Maintain all tools and machines in peak condition Keep tools sharp and clean for best and safest performance Follow instructions for lubricating and changing accessor...

Страница 4: ...ct will expose you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling California Health Safety Code 25249 5 et seq The warnings precautions and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur It must be understood by the operator that common s...

Страница 5: ...D You will need the following tools to assemble and adjust the machine The tools are not included 19 mm wrench or adjustable wrench SET UP WARNING Always place the ON OFF switch in the OFF position and unplug the power cord from its power source before performing any assembly or adjustment Failure to do so could result in accidental starting resulting in possible serious personal injury WARNING To...

Страница 6: ...3 WARNING Do not permit fingers to touch the terminals of plug when installing or removing from outlet Inspect tool cords periodically and if damaged have it repaired by an authorized service facility The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment grounding conductor If repair or replacement of the electric cord or plug is necess...

Страница 7: ...its power source before performing any assembly or adjustment Failure to do so could result in accidental starting resulting in possible serious personal injury WARNING To prevent serious injury from tool failure do not use damaged equipment If abnormal noise or vibration occurs have the problem corrected before further use GENERAL MAINTENANCE WARNING Repairs to the bench buffer should be performe...

Страница 8: ...ries Motor runs hot 1 Motor is overloaded 1 Reduce pressure on workpiece 2 Poor air circulation around motor 2 Remove any blockage around motor 3 Accessory is dull or damaged 3 Replace accessory always use sharp accessories 4 Undersized or excessive length of extension cord 4 Use correct size Fuse blows or circuit breaker trips 1 Motor is overloaded 1 Reduce pressure on workpiece 2 Overloaded elec...

Страница 9: ...NOTE ...

Страница 10: ...6 HEAVY DUTY BENCH BUFFER PARTS ILLUSTRATION 8 PARTS LIST 8 ...

Страница 11: ... Cord clamp 1 13 BF600013 Stator 1 14 BF600014 Rotor 1 15 BF600015 Hard buffing wheel 1 16 BF600016 I type hex nut M12 1 17 BF600017 Hex flange nut M5 2 Key No Part Description Specification Qty 18 BF600018 Fan 1 19 BF600019 Outer toothed locking washer D4 1 20 BF600020 Philips screw spring washer flat washer M4x8 2 21 BF600021 Switch 1 22 BF600022 Switch plate 1 23 BF600023 Cord bushing 1 24 BF60...

Страница 12: ...st present the proof of purchase documentation which includes a date of purchase POWERTEC will either repair or replace any defective part at our option at no charge to you The repaired or replacement unit will be covered by the same limited warranty for the balance of one year warranty period WHAT IS NOT COVERED This warranty applies to the original purchaser at retailer and may not be transferre...

Страница 13: ...NOTE ...

Страница 14: ...NOTE ...

Страница 15: ...NOTE ...

Страница 16: ...Southern Technologies LLC 3816 Hawthron CT Waukegan IL 60087 ...

Отзывы: