INDEX
47
QUATTROCANALI | SERVICE MANUAL
12. 4CH / 2CH Platform DSP Rescue Procedure
1. Connect the PC to the amplifier via ETH port
2. Set the PC IP address as
192.168.5.100.
The subnet mask will be automatically set.
3. Copy the file “
upgrade4-v1.7.6.74.zip
” in local PC
4. Rename the file “
upgrade4.zip
”
5. On the front panel of your amplifier keep pressed four (4) push buttons all together:
CALL / SOFT RESET / HARD RESET / CHECK
6. Power up the amp with the 4 buttons still pressed
7. Verify that all front leds turn ON