9  TECHNICAL DATA 

Type 

POWX1724S 

Rated voltage

 

230V

 

Rated frequency 

50 Hz 

Rated Power 

550 W / 0,75 pk 

Rotation speed 

1500 min

-1

 

Rated Pressure 

8 bar 

Tank capacity 

6 l 

Air debit (capacity) 

105 l/min 

 

10 NOISE 

Noise emission values measured according to relevant standard. (K=3) 

Acoustic power level LwA 

79 dB(A) 

ATTENTION! Wear hearing protection when sound pressure is  
over 85 dB(A). 

11 WARRANTY 

 

This product is warranted for a 36-month period effective from the date of purchase by the 
first user. 

 

This warranty covers all material or production flaws excluding : batteries, chargers, 
defective parts subject to normal wear & tear such as bearings, brushes, cables, and 
plugs, or accessories such as drills, drill bits, saw blades, etc. ; damage or defects 
resulting from maltreatment, accidents or alterations; nor the cost of transportation. 

 

Damage and/or defects resulting from inappropriate use also do not fall under the 
warranty provisions. 

 

We also disclaim all liability for any bodily injury resulting from inappropriate use of the 
tool. 

 

Repairs may only be carried out by an authorised customer service centre for Powerplus 
tools. 

 

You can always obtain more information at the number 00 32 3 292 92 90. 

 

Any transportation costs shall always be borne by the customer, unless agreed otherwise 
in writing. 

 

At the same time, no claim can be made on the warranty if the damage of the device is the 
result of negligent maintenance or overload. 

 

Definitely excluded from the warranty is damage resulting from fluid permeation, excessive 
dust penetration, intentional damage (on purpose or by gross carelessness), inappropriate 
usage (use for purposes for which the device is not suitable), incompetent usage (e.g. not 
following the instructions given in the manual), inexpert assembly, lightning strike, 
erroneus net voltage. This list is not exhaustive. 

 

Acceptance of claims under warranty can never lead to the prolongation of the warranty 
period nor commencement of a new warranty period in case of a device replacement. 

 

Devices or parts which are replaced under the warranty  therefore remain the property of 
Varo NV. 

 

 We reserve the right to reject a claim whenever the purchase cannot be verified or when it 
is clear that the product has not been properly maintained. (Clean ventilation slots, carbon 
brushes serviced regularly, etc.). 

 

Your purchase receipt must be kept as proof of date of purchase. 

Содержание POWX1724S

Страница 1: ...fety 3 5 3 Personal safety 3 5 4 Power tool use and care 4 5 5 Service 4 6 SPECIFIC SAFETY WARNINGS 4 6 1 Do s 4 6 2 Don ts 5 7 USE OF THE COMPRESSOR 6 7 1 Voltage 6 7 2 Switching ON OFF 6 7 3 Adjusting the pressure 6 7 4 Safety valve 6 7 5 Fitting the air filter 6 8 CLEANING AND MAINTENANCE 6 8 1 Maintenance 6 9 TECHNICAL DATA 7 10 NOISE 7 11 WARRANTY 7 12 ENVIRONMENT 8 13 DECLARATION OF CONFORMI...

Страница 2: ... PACKAGE CONTENT LIST Remove all packing materials Remove remaining packaging and transit supports if existing Check the completeness of the packing content Check the appliance the power cord the power plug and all accessories for transportation damages Keep the packaging materials as far as possible till the end of the warranty period Dispose it into your local waste disposal system afterwards WA...

Страница 3: ...g a power tool will increase the risk of electric shock Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock When operating a power tool outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces th...

Страница 4: ... tool s operation If damaged have the power tool repaired before use Many accidents are caused by poorly maintained power tools Keep cutting tools sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to stick and are easier to control Use the power tool accessories and tool bits etc in accordance with these instructions and in the manner intended for the parti...

Страница 5: ... 15 means 1 5 minutes On 8 5 minutes OFF In case of overheating the thermal cutout of the motor is released automatically cutting off the power when the temperature is too high due to excess current take off The motor restarts automatically when normal temperature conditions are restored 6 2 Don ts Never direct the jet of air towards persons animals or your body Never let the compressor come into ...

Страница 6: ...ohibited to adjust the safety valve or remove its seal Actuate the safety valve from time to time to ensure that it works when required Therefore you need to remove the protection cover 7 5 Fitting the air filter Remove the transportation stop with a screwdriver or similar and screw the air filter Ref I securely to the equipment Fig 1a 1b If supplied insert the suction tube inside the filter cover...

Страница 7: ...ut by an authorised customer service centre for Powerplus tools You can always obtain more information at the number 00 32 3 292 92 90 Any transportation costs shall always be borne by the customer unless agreed otherwise in writing At the same time no claim can be made on the warranty if the damage of the device is the result of negligent maintenance or overload Definitely excluded from the warra...

Страница 8: ... accompanied by proof of purchase 12 ENVIRONMENT Should your appliance need replacement after extended use do not discard it with the household rubbish but dispose of it in an environmentally safe way Waste produced by electrical machine items should not be handled like normal household rubbish Please recycle where recycle facilities exist Check with your Local Authority or retailer for recycling ...

Страница 9: ...ication of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2014 30 EU 2006 42 EC 2000 14 EC Annex VI LwA measured 76dB A guaranteed 79dB A Testing Authority Eurofins Italy European harmonized standards including if applicable their amendments up to the date of signature EN1012 1 2010 EN60204 1 2018 EN55014 1 2...

Отзывы: