Figure 3
5
SETTING
Your air tool is fully assembled when you receive it.
After you have adjusted the stapler foot to a sample
of your fl ooing and you are ready to use it, attach the
air line and any desired air system accessories. Be
sure the air hose is depressurized when installing or
removing adapters to the air line. To prevent misfi re,
do not connect air to a loaded nailer.
Figure 2
STA PLER
QUICK
CONNECTOR
AIR HOSE
CONNECTING THE TOOL TO AN AIR SUPPLY
1. An automatic airline oilier is recommended but oil may be
added manually before every operation or after about 1 hour of
continuous use.
2. Place two (2) drops of air-tool oil in the air plug as shown in
Figure 3. If you are using an automatic in-line oiler, check and
add oil if necessary.
3. Turn your compressor on and set the compressors pressure
regulator to the proper pressure for the size and type of fastener
being used. Normal operating pressure should be adjusted
between 70-110 psi based on fastener and wood being used.
4. Connect the tool to the air supply (fi gure 2).
OPERATION,
continued...
LOADING THE FASTENERS
1. Depress the LOCK(60) to release the
MOVABLE
MAGAZINE (44) and pull the magazine out fully
as shown in Figure 3.
2. Place a full clip of the specifi ed type and size
fasteners on the FIXED MAGAZINE (51), up to
125 fasteners may be loaded in the magazine.
3. Push the MOVABLE MAGAZINE ASSEMBLY
forward until it is locked.
FIXED CHANNEL
MOVABLE
MAGAZINE UNIT
60
44
51